SEM and EDS Analysis of Ti-13Ta-1Cu Alloy Obtained by Mechanical AlloyingTITANIUM alloysSCANNING electron microscopyBIOCOMPATIBILITYdoi:10.1093/micmic/ozad067.403A. MedinaC. AguilarL. J. SandovalS. BorjasS. PachecoJair Leopoldo Loaiza Bernal
1 shows the scanning electron microscope (SEM) images of HNG and reduced GO (rGO). An rGO layer exhibits a large and flat area whereas HNG becomes porous. The transmission electron microscope (TEM) images in Supplementary Fig. 2 further reveal the successful synthesis of micropores on HNG. ...
These results, in agreement with the SEM/EDS measurements, indicate that Cu(II) can more easily replace Na+ than Ca2+ on the cation exchange surface of the sorbent probably as a result of their different ionic radius and hydration energy (Teutli-Sequeira et al. 2009). Sorption mechanism ...
Scanning electron microscopy (SEM; Hitachi S-4800) was employed to examine the morphology and size of the samples in both aqueous and organic phases. X-ray diffraction (XRD) analysis of dried samples from the aqueous phase was conducted using Cu Kα radiation (λ = 1.54056 Å) in ...
As depicted by the Scanning Electron Microscope (SEM) images (Fig. 2a and Supplementary Figs. 1 and 2), the as-prepared CuO exhibit flaky morphology. Upon the introduction of Ag, rod-shaped particles with diameters ranging from 500 nm to 2 µm become dominant in the CuAg oxides. ...
Cuproptosis differs from other forms of cell death, such as apoptosis, necroptosis, and ferroptosis, in its unique molecular mechanisms and signaling pathways. In this review, we delve into the cellular metabolic pathways of copper, highlighting the role
The structure determines performance. Therefore, the information of morphology, composition, and crystallography for Cu@CuO was analyzed by SEM and TEM (Fig. 3), respectively. In a low-magnification SEM image (Fig. 3a), Cu@CuO exh...
Fig. 5. (a) SEM image of nt-Cu microbump arrays after CMP, and the inset image shows an as-deposited nt-Cu microbump. (b) Focused Ion Beam analysis of a microbump. (c) EBSD analysis of surface orientation of an nt-Cu microbump. [35]. Show moreView article Surface Structure and...
Elemental analysis of samples was obtained using the EDS accessory (Oxford Instruments, Inca X-sight, model 7426) of the SEM. The GI-XRD data were obtained using a Bruker D8 Discovery High resolution X-ray Diffractometer at incidence angle of 2° and wavelength of 1.54 Å. The double-...
time plots measured for Ru@Cu-TM and Pt/C-TM benchmark; f SEM image of Ru@Cu-TM after CP test (200 h at −200 mA/cm2). Scale bar: 1 μm. g Comparison between the HER activity of our Ru@Cu-TM and PGM-based electrocatalysts for the HER in 1 M KOH/NaOH reported ...