A Current‐Sourced Converter (CSC) ‐ High Voltage Direct Current Transmission (HVDC) link can be either long distance or back‐to‐back (BTB). In a long‐distance HVDC system, the rectifier and inverter stations are connected via an overhead line or cable or a combination of both. In a...
必应词典为您提供csc-hvdc的释义,网络释义: 电流源型高压直流输电;直流输电系统;
本发明公开了一种基于CSC‑HVDC阀组间交互模型的故障分析方法,该方法包括获取待检测的CSC‑HVDC系统的工作状态电气参数,构建用于进行故障分析的CSC‑HVDC阀组间交互模型,将所述待检测的CSC‑HVDC系统的工作状态电气参数作为所述CSC‑HVDC阀组间交互模型的输入,输出得到待检测的CSC‑HVDC系统的动态特征参数,进...
The Flexible CSC is also free to control the amplitude and phase of its output ac current. So, it can control freely active power and reactive power. Use this converter to construct a new CSC-HVDC system. This new CSC-HVDC system can operate in four quadrants, so as to control reactive...
The Flexible CSC is also free to control the amplitude and phase of its output ac current. So, it can control freely active power and reactive power. Use this converter to construct a new CSC-HVDC system. This new CSC-HVDC system can operate in four quadrants, so as to control reactive...
A Current-Sourced Converter (CSC) - High Voltage Direct Current Transmission (HVDC) link can be either long distance or back-to-back (BTB). In a long-distance HVDC system, the rectifier and inverter stations are connected via an overhead line or cable or a combination of both. In a BTB...
CSCStabilityFault analysisEfficient and economic power delivery through HVAC transmission system over long distance is a great challenge due to its physical and operational constraints. HVDC systems are preferable for long-distance transmission due to the technical and economic superiority over HVAC systems...
CSC-HVDC 输电线路单端行波自 动故障定位方法[J]. 高电压技术,2014,40(2):588-596. SONG Guobing, JIN Donghui, JIN Xingfu, et al. Automatic fault lo- cation method for traveling wave on HVDC transmission line using single-terminal data[J]. High Voltage Engineering, 2014, 40(2): 588-596...
SMESPower FluctuationThis research proposes the power compensation for fluctuation power in CSC-HVDC (High Voltage DC Transmission using Current-Source Converter) with series connected SMES (Superconducting Magnetic Energy Storage). The objective of this system is to smooth out fluctuating power in one ...
HVDC transmission systemfault protection technique鈥擳his paper introduces a novel approach to highspeed fault protection strategy for bipolar Current Source Converter (CSC) based high voltage DC transmission line. The Bagged-Tree Ensemble-Classifier (BTEC) method is employed to detect the presence of ...