将NID 从18/24 提高到30/40 增加自动终止的事件* • 较长的NID意味着实际的治疗时间增加3-4秒** *During Induction testing the NID is termporarily set to 18/24 (RNID 12/16) ** 30/40 detection is 12 additional beats ycle length of 250-300ms 3 Medtronic InSyncÒ ICD Data on-file ...
Having these long-term data on the magnitude of the expected benefit of CRT-D implantation will be useful when discussing treatment options with patients, Sapp indicated. “If you have to weigh that against risks of a procedure, for example, getting a really good understanding of the potential...
CRT/CRTD治疗心力衰竭的研究进展 对于存在室性心律失常危险因素的患者加植埋藏式心脏复律除颤器(ICD),即可预防心源性猝死的发生,显著降低病死率。因此,CRT/CRTD在心力衰竭的治疗中拥有广阔的前景... 庄颖珠(综述),晋群(审校),张吉新(审校) - 《医学综述》 被引量: 17发表: 2011年 Reduced long-term overal...
ICD 降低全原因住院和死亡率;降低心源性死亡;增加总生存率;改善运动能力 第70页,共90页,编辑于2022年,星期日 主要研究终点: CRT和CRT-D均明显降低全原因死亡率和全原因住院率的复合终点 第71页,共90页,编辑于2022年,星期日 CRT 和CRT-D均显著降低死亡率或心血管原因住院率 第72页,共90页,编辑于2022年,...
还增加了对心脏除颤器功能的评价(包括双室起搏抗心律失常的疗效)心力衰竭心脏再同步(CRT)治疗369例患者被随机分组,182例为对照组(接受心脏除颤器治疗,但不接受CRT),187例为试验组(联合CRT、心脏除颤器治疗)心力衰竭心脏再同步(CRT)治疗生活质量评分改善P0.02心力衰竭心脏再同步(CRT)治疗心功能分级改善P0.01CRT-D...
Besides being thelongest-lasting 1.5 and 3T full body MRI-conditional CRT-D1,2, Gali 4LV™ guarantees continuous, advanced patient care while device dimensions, design and preset programming make implantation, and follow-up effortless. AUTOMRI™ adaptive intelligenceallows Gali™ to automa...
G547RESONATE™ HF CRT-D G447RESONATE™ X4 CRT-D Reimbursement C-Code: C1882 See all reimbursement resources Education and training Educational Resources Explore CRT-D training and resources, best practices modules, medical training, and continuing education courses. ...
has been shown to be an independent predictor of clinical events and worsened survival in pa-tients with heart failure and has correlated better than the QRS duration with the long-term ben-efit of CRT.4 Accordingly, multiple noninvasive techniques have been used to identify mechanical dys...
H Burri - 《Expert Review of Medical Devices》 被引量: 129发表: 2014年 Heart rhythm disorders and pacemakers:Long-term effects of cardiac resynchronisation therapy in patients with atrial fibrillation Objective: To compare the effects of cardiac resynchronisation therapy (CRT) in patients with heart...
Patient with primary hypokinetic dilated cardiomyopathy, previously underwent coronary angioplasty with stent implantation on MO branch and subsequent implantation of CRT–D in right subclavian region for persistence of left superior vena cava and complicated left sided implantation; hypertensive, dyslipidae...