Re: caution: Memory correctable Error Threshold Exceeded This would indicate that the memory module in slot 2 of the system board (128 Meg) needs to be replaced. 0 Kudos Reply The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. By ...
I received the following error on Integrated log - "Processor Correctable error threshold exceeded (Slot0, Socket1)." Now what does this mean? The server is DL560 and has 4 processors. Per above error which processor has the problem and how to fix it. Thanks. ...
ECC correctable errors represent a threshold overflow for a given Dual In-line Memory Modules (DIMM) within a given timeframe. if there is no catastrophic issue (Purple Screen Of Death (PSOD) or unexpected restart), and the correctable ECC error including Adaptive Double Device Data Correction ...
The PFA Threshold limit (correctable error logging limit) has been exceeded on DIMM number [arg1] at address [arg2]. MC5 Status contains [arg3] and MC5 Misc contains [arg4]. DIMM PFA Threshold Exceeded Severity Error User Response
In response to determining that the number of correctable errors on the first bus interface exceeds the error threshold, at least a portion of I/O requests are redirected to use a second bus interface to connect to a second device adaptor providing a second connection to the storage.Matthew G...
For these reasons, starting with UCS Manager (UCSM) 2.2(7), 3.1(1), and Cisco Integrated Management Controller (CIMC) 2.0(9) for rack standalone servers, Cisco UCS server memory-error threshold policies will not declare modules with correctable errors to be degrade...
and the correctable ECC error, including Adaptative Double Device Data Correction (ADDDC) error, is less than10 events every 24 hours for each DIMM location, which is within the threshold limit, the recommendation is tomonitorthe server for any recurrence of ECC error each DIMM location that tr...
An internal error has occurred in Jordan Creek. The number of errors that occur during data transmission between Jordan Creek and the memory controller has reached the alarm threshold. Procedure Check whether there is any alarm generated for the memory board or DIMM correspondin...
I wonder is this event mean only one bit error occurred in the dimm or the number of error occurred in that dimm exceeded the threshold? If it is the first case, I think it is ok, and won't lead to any server health problem. I hope someone can help me with this! Translate ...
In response to determining that the number of correctable errors on the first bus interface exceeds the error threshold, at least a portion of I/O requests are redirected to use a second bus interface to connect to a second device adaptor providing a second connection to the storage.MATTHEW G...