Heat Load (BTU/Hr) = GPM X 500 X ° Range of cooling, or rearranged to determine the design flow rate. GPM = Heat Load (BTU/Hr) = 6,250,000 Btu/Hr = 835 gpm 500 X ° Range of cooling 500 x 15° R Now you can make your cooling tower selection based on 835 gpm, cooling f...
This paper explains the widely-used total-heat method of calculation, referred to as the Merkel solution. -The approximations by which simplification is effected are discussed in terms of practical significance. The paper proceeds to outline the principles governing selection of packing, water ...
1) selection of cooling towers 冷却塔选型2) FNT genre refrigerant tower FNT型冷却塔 1. The design about intensity of the structure in FNT genre refrigerant tower is calculated theoretically. 针对FNT型冷却塔结构强度的设计问题进行了理论计算,根据材料力学理论方法,得到了冷却塔各部件的强度值,结果...
According to the characteristic for the production of cooling tower,the paper put forward a new method to calculate the production cost of cooling tower.The method focuses on the whole material used in the production,rather than to calculate the material used in each component.After that,rough se...
Determine the chiller cooling capacity, water flow and return water temperature, optional cooling tower, expansion tank, manifolds, and their selection calculation; 翻译结果2复制译文编辑译文朗读译文返回顶部 The definite cold water unit's refrigeration quantity, the discharge of water and for the backwa...
system.As viewed from the working characteristics of cooling tower turbine,this paper puts forward approximate calculation formula to estimate its flow capacity,according to the flow parameters of the special turbine.And the field test results are used to test the correctness of the approximate ...
Maisotsenko cycle; wet cooling tower; wet-bulb effectiveness; parallel counter-flow arrangement fills1. Introduction The traditional wet cooling tower (TWCT) is considered to be one of the key components of electricity generation systems, as well as an important factor affecting the total ...
The tower-type will be discussed in subsequent articles. The main dimensions of the studied MCTs with S-wave fill are shown in Table 1. Figure 1. Physical model. Table 1. The main dimensions of the studied wet cooling towers (mechanical draft wet-cooling towers (MCTs)). Based on the...
the book is organized into three sections. section a on cooling tower practice covers topics such as the design and operation of cooling towers; types of cooling tower; cooling tower components and construction materials; practical aspects of tower selection; industrial applications; and water quality...
This paper explains the widely-used total-heat method of calculation, referred to as the Merkel solution. -The approximations by which simplification is effected are discussed in terms of practical significance. The paper proceeds to outline the principles governing selection of packing, water distribut...