This is a seven-year study (1/7/2011-31/12/2017) of radon monitoring at two sites of Campi Flegrei caldera (Neaples, Southern Italy) that in the last 70 years experienced repeated phases of volcanic unrest. The sites are equipped with devices for radon detection, based on the ...
A device for the continuous monitoring in situ of radon concentration in ambient air, and the simultaneous measurement of working level (WL) values of the radon daughters in ambient air. The device comprises an electrical field formed of two hemispherical walls facing each other with a gap ...
This is a seven-year study (1/7/2011-31/12/2017) of radon monitoring at two sites of Campi Flegrei caldera (Neaples, Southern Italy) that in the last 70 years experienced repeated phases of volcanic unrest. The sites are equipped with devices for radon detection, based on the spectrometr...
RAD AQUA Continuous radon in water monitoring for the RAD7 Big Bottle System High sensitivity radon in water sampling for the RAD7 Water Probe For radon sampling from large bodies of water DRYSTIK Active moisture exchanger to reduce the humidity of the air entering the RAD7 Soil Gas Probes Ex...
Response of the Savannah River impactor-type alpha continuous air monitor to plutonium and radon progeny The Savannah River Site (SRS) impactor-type alpha continuous air monitor (CAM) is an innovative, high-volume, real-time alpha air monitoring system. It was... MD Hoover,BT Chen,GJ Newton...
Type Digital Gas Detector Other attributes Customized support OEM, ODM Place of Origin Guangdong, China Material Aluminum alloy Warranty 1 Year Brand Name GZAIR Model Number PT07 Power Electronic Usage Other, Household Product name Smart Radon Gas Detector ...
Integrated passive measure systems (e.g track etched detectors) give only information about average radon concentrations. However in many situations, this value do not provide enough information about the real exposure of workers because the knowledge on the evolution of radon concentration is needed....
The Radon-222 concentrations in the air in Nerja Cave (Spain) (3o52′35′′W 36o 43′50′′N) have beenmeasured by continuous monitoring using Alfa-Guard, Genitron instruments equipment, model PQ-2000-PRO.The measurements of the ~(222)Rn were carried-out during a complete annual cycle ...
(2000) - Groundwater, radon continuous monitoring system (α-scintillation counting) for natural hazard surveillance. Pure and Applied Geophysics, 157, 407-433.Galli, G., Mancini, C. and Quattrocchi, F., 2000, Groundwater radon continuous monitoring system (a-scintillation counting) for natural ...
We present the results of a long term, continuous radon monitoring experiment started in April 2010 in a seismically active area, affected during the 2010-2013 data acquisition time window by an intense micro seismic activity and by several small seismic events. We employed both correlation and ...