P. Bocca, "The application of pull-out test to high strength concrete estimation," Mate´riaux et Constructions, vol. 17, no. 3, pp. 211-216, 1984.Bocca P. The application of pull-out test to high strength concrete estimation. Materials and Structures. 1984 May;17(3):211 -6....
PULL-OUT TEST OF ANCHOR BOLT FOR FASTENING LEAD DAMPER TO CONCRETE FOUNDATION Because slipping failure lead to decrease in tensile strength and increase in pull-out displacement at failure. (3) The slope of the concrete cone was ... H Asada,S Kishiki,A Wada - 《J.struct.constr.eng》 被...
This study focuses on the results of the comprehensive strength test to quantify the mechanical properties of the screw's pullout strength on foamed concrete. Foamed concrete is classified as lightweight concrete that been produced by cement paste or mortar in which air-voids are entrapped in the...
Standard Test Method for Pullout Strength of Hardened Concrete 1.1\n本试验方法包括通过测量从混凝土试样或结构中拉出嵌入金属嵌件和附着混凝土碎片所需的力来确定硬化混凝土的抗拔强度.插入件要么浇注在新浇混凝土中,要么安装在硬... C. - C09.64 被引量: 0发表: 2019年 The post-installed screw pull-out...
As existing research on the pullout behavior of metallic anchors is partially relevant to FRP anchors, this paper first presents a review of current pullout strength models for metallic anchors. These models are then assessed with experimental data of FRP anchors and modified and recalibrated where...
40 multi-functional strength tester is suitable for testing the concrete(C10~C80) strength and External wall tapestry brick bonding strength on site, and also suitable for testing the other pull strength. It adopts the Post-install pull-out test method for testing the concrete strength throu...
The pull-out post-insert method used for testing high-strength concrete strength is studied with the pull-out testers of ring-type stabilizer and three-point stabilizer.On the basis of the experiment research,the relationship of the pulling resistance and compressive strength of high-strength concret...
In this paper, the authors present results of an experimental program carried out to study the pull-out behavior of a new type of high yield strength steel deformed reinforcing bars (f sub y = 830 MPa) embedded in high strength concrete (f sub c = 100 MPa). Influence of embedded length...
Test results indicate that significant bond strength exists to resist the pull out of a concrete core from a steel pipe in a tension joint. This is true even after 1100 high load cycles and after a year of exposure to severe weather. Measurements of strain distribution and slip were made on...
Degradation of bond strength due to corrosion of steel strands is of great importance for serviceability of prestressed concrete structures. An analytical model is proposed to demonstrate the effect of corrosion of steel strand on reduction of bond stren