PURPOSE: To provide the title method wherein the lower opening of each sleeve joint is not shut with mortar injected from the outside of a column into a clearance between the column and a slab, before grouting material is injected into the sleeve joints.YOSHIMATSU KENJI...
With the purpose of identifying and highlighting gaps in the published literature, a review of tests with HSC, FRC and UHPFRC slab-column connections in non-seismic and seismic loading applications is presented in this paper. It is shown that future research directions in this field include, ...
In a slab-beam-column type construction in multistory building the practice is to many times use higher strength concrete in columns as compared to beams and slabs. The concrete is placed in the following stages: 1. Column is cast up to bottom of beam using high stength concrete. 2. ...
The third beam is also a reduced beam section, but with a restraint from the reinforced concrete slab at the top flange. The initial stiffness, hysteretic behavior, failure mode and capacity of each beam-to-column connection are presented and discussed....
摘要: Strength and Rigidity of Joint Panel of Concrete Filled CHS Column-to-Beam Connection KAMBA Teruyasu Proceedings of the Third ASCCS International Conference on Steel-Concrete Composite Structures, 189-194, 1991被引量: 12 年份: 1991
1) reinforced concrete slab column connection 钢筋混凝土板柱节点1. In this paper,an experimental study is presented on the punching failure of reinforced concrete slab column connection,which is simply supported at the edges and loaded by TNT group charge explosions. 在TNT集团装药爆炸作用下 ,...
CONNECTION PART STRUCTURE OF PRECAST CONCRETE COLU 优质文献 相似文献Experimental study on seismic behavior of precast concrete layered slab and beam to column interior joints In order to study the seismic performance of beam to column joints of high-rise precast concrete structure,the interior joints ...
Lee et al. [38], for instance, verified the performance of the TVS, which applies lightweight balls to the concrete slab in two-way voided slab-to-column connections. According to Chung et al. [39], the flexural capacities of the two-way voided slab system that is associated with donut...
punching shear; punching cone; slab-column connection; fiber reinforced polymer; carbon fiber; yield line Graphical Abstract1. Introduction The use of fiber reinforced polymer (FRP) to strengthen concrete structural members has greatly increased in recent decades [1,2]. Various advanced composite ...
Precast joint for seismic areas: foundation-to-column-dowel connection Precast joint for seismic area: wall-to-floor/half slab_connection Precast joint for seismic areas: wall-to-wall connection Precast joint for seismic areas: wall corner connection ...