PROBLEM TO BE SOLVED: To provide a concrete foundation column capable of improving site workability by avoiding mutual interference between an anchor bar and a column bar in the case the anchor bar provided inside of a footing as a foundation of a concrete structure is connected to the column ...
Details of steel structure connection on old concrete structure. The joint performance of the concrete and steel columns in the transfer floor had to be ensured that due to the calculated dimensions of the steel column, it could not be properly buried in the concrete column. It was decided to...
Accordingly, the concrete model has no remarkable influence on the behavior of the composite column at this stage. By contrast, the peak point and the postpeak region of the curve are highly dependent on the confinement mechanism of the composite column. Table 4.2. Geometric and material ...
aThe foundation top and between the column foot ledger wall must two times water C40 does not have contracts the thin stone concrete or the iron filings mortar, when the construction should use the pressure grouting. La tapa de la fundación y entre la pared del libro mayor del pie de la ...
Table 1 Bayes factor (BF) values for model comparison between the model carried out using the Type of sentences as the factor with the Null Hypothesis model (only intercept) (first column); the model carried out using the Kind of concepts as the factor with the Null Hypothesis (only interce...
5. Details 5-1B Concrete Masonry Veneer Details (2003) 5-2A Clay & Concrete Masonry Banding Details (2002) 5-2C CAN-TEK Clay and Concrete Masonry Banding Details (2014) 5-3A Concrete Masonry Foundation Wall Details (2003) 5-4B Concrete Masonry Residential Details (2002) ...
Damage Mitigation for Precast Concrete Column-to-Pile Shaft Member Socket Connections Designing precast concrete substructure connections, which adjoin a column to its foundation/cap beam, for satisfactory seismic performance is a daunting c... H He,C Yang - Canadian Society of Civil Engineering Confe...
Concrete-filled square steel tubular (CFSST) stub column stiffened with an encased I-section carbon fiber-reinforced polymer (CFRP) is a new composite member that consists of a square steel tube, concrete infill, and an encased CFRP profile. This paper conducted investigations that experimentally ...
The flange projects out from the tube a distance equal to 16 times the wall thickness of the tube to interlock the CFT column with the foundation and penetrates into the concrete fill a distance equal to 8 times the wall thickness. No shear connectors, dowels, or internal reinforcement are ...
1) Reinforced concrete column foundation 现浇钢筋混凝土立柱基础2) cast-in-situ reinforced concrete 现浇钢筋混凝土 1. Nonlinear finite element analysis on cast-in-situ reinforced concrete hollow slab; 现浇钢筋混凝土空心板非线性有限元分析 2. Experimental research on mechanical behavior of the cast-in...