Compton cameraPROBLEM TO BE SOLVED: To provide an inexpensive Compton camera, capable of being miniaturized, with high resolution by three-dimensionally grasping the incident position of incident radial rays (for example, gamma rays).片岡 淳岸本 彩加藤 卓也...
The scope of the current project was to determine an optimal design and configuration of a Compton camera that strikes a balance between these two properties. Transport of the photon flux from the source to the detectors was simulated with the camera geometry serving as the parameter to be ...
energy measurement. Other factors, such as camera geometry and spatial resolution of the detectors, affect the angular un- certainty as well [ 1,2,5]. In this paper, we analyze the effects of energy uncertainties on the calculation of the scatter angle. These uncertainties ...
The Compton camera has been proposed as an alternative to the Anger camera in SPECT. The advantage of the Compton camera is its high geometric efficiency due to electronic collimation. The Compton camera collects projections that are integrals over cone surfaces. Although some progress has been made...
we present a high-precision image of 4.4 MeV gamma rays taken by newly developed 3-D position sensitive Compton camera (3D-PSCC). To mimic the situation in proton therapy, we first irradiated water, PMMA and Ca(OH)2 with a 70 MeV proton beam, then we identified various nuclear lines...
By using a prototype Compton camera consisting of silicon (Si) and cadmium telluride (CdTe) semiconductor detectors, originally developed for the ASTRO-H satellite mission, an experiment involving imaging multiple radiopharmaceuticals injected into a living mouse was conducted to study its feasibility for...
A narrow-FOV Compton telescope can be realized by installing a Si/CdTe Compton Camera inside the deep well of an active shield. This configuration is very suitable as focal plane detector for future focusing gamma-ray missions. 展开 关键词:...
The Compton camera is an imaging device relevant for the detection of prompt photons produced during nuclear fragmentation in hadrontherapy. It allows a considerable improvement in detection compared to a standard gamma-camera but also requires more sophisticated image reconstruction techniques. In this ...
In this paper we study the image resolution that can be obtained from the Multiple Coincidences Compton Camera (MCCC). The principle of MCCC is based on a simultaneous acquisition of several gamma-rays emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can...
Compton imaging exploits inelastic scattering, known as Compton scattering, using a Compton camera consisting of a scatterer detector in the front layer and an absorber detector in the back layer. This method was developed for astronomy, and in recent years, research and development for environmental...