Error: CMSIS-DAP command CMD_DAP_SWJ_CLOCK failed. 解决方法:需要指明调试速率,添加速率指示语句之后,错误消失。 ./openocd.exe -s ../tcl -f interface/cmsis-dap.cfg -f target/rp2040.cfg -c "adapter speed 5000"
> halt target halted due to debug-request, current mode: Thread xPSR: 0x81000000 pc: 0x000005c0 msp: 0x20000870 > flash write_image erase DZ.hex auto erase enabled Flash operation not possible in current run mode: SMC_PMSTAT: 0x0 Issue a 'reset init' command. failed erasing sectors 0...
CMSIS DAP调试器通常以接口芯片的方式呈现,以USB电缆运行调试器的主机,以JTAG或者SWD接口连接芯片的开发板。 主机与开发板直接通过交换一系列通讯实现调试,通常主机发送命令(command)而开发板回复响应(response)。借助CMSIS DAP调试器支持的JTAG命令,开发人员可以利用标准的CMSIS DAP调试器,调试HPM6000系列RISC-V高性能微...
Error: CMSIS-DAP command CMD_DAP_SWJ_CLOCK failed. Assertion failed: jtag_trst == 0, file src/jtag/core.c, line 343 ESP_Gargamel Posts:786 Joined:Wed Nov 14, 2018 8:45 am Re: 关于openocd,用cmsis-dap时报错 PostbyESP_Gargamel»Tue Jul 27, 2021 11:45 am ...
棒好完美
/// Used for the command \ref DAP_Connect when Port Default mode is selected. #define DAP_DEFAULT_PORT 1U ///< Default JTAG/SWJ Port Mode: 1 = SWD, 2 = JTAG. /// Default communication speed on the Debug Access Port for SWD and JTAG mode. ...
上文提到了,CMSIS-DAP是基于命令式的处理,调试器从PC接收指令(Command/Request),在处理结束后调试器整理好结果(Response)发送回PC。由于没有Outstanding(但是可以有内部缓冲),因此指令是顺序执行的,类似于FIFO的架构。因此,CMSIS-DAP的固件内部是一个大的循环,PC端发送的数据会先置于一个FIFO中,待DAP_Thread函数读取...
Reset Target Device with custom specific I/O pin or command sequence. This function allows the optional implementation of a device specific reset sequence. It is called when the command DAP_ResetTarget and is for example required when a device needs a time-critical unlock sequence that enables...
I keep getting a "CMSIS-DAP command CMD_INFO failed." error. I know that OpenOCD is working because I have been using the LPCXpresso824-MAX board as a CMSIS-DAP debugger for the on board LPC824 and it works fine. I have tried both running OpenOCD to talk to the LPC-Link2 w...
shutdown command invoked *** [upload] Error 1 === [FAILED] Took 1.82 seconds === * 终端进程“platformio 'run', '--target', 'upload'”已终止,退出代码: 1。 * 终端将被任务重用,按任意键关闭。 ---