Connected with an external oximeter probe Wireless communication function(CMS60DW)Main performance Display Mode: 1.8" Color OLED display Screen Resolution: 160*128 SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%: ± 2%, Below 70% unspecified. PR ...
Pulse waveform display: Bargraph display Low battery indication: LED display Power supply Requirement: 1.5V(AAAsize) Alkaline Batteries× 2; Working current: ≤ 25mA Resolution: SPO2: 1% Pulse Rate: 1bpm Accuracy: SPO2: 70%to100%± 2digits, below70%unspecified Pulse rate: ± 2bpm...
This fingertip pulse oximeter is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having...
-Accuracy 70% ~ 100% ±2%; 0% ~ 69% unspecified -Measuring range for pulse rate 0~250bpm -SpO2 probe SpO2 probe for adult, pediatric and neonatal are optional NIBP -Method Oscillometry -Mode Manual, Auto, Continuous -Measuring Period in Continuous Mode 5 Min...
Accuracy: ±1% or ±1bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy: -0.8mv~+0.8mv ±0.04mV or ±10%, whichever is greater Other range...
Measurement accuracy for PR: ±2bpm or ±2%, whichever is greater. Pulse modulation volume: yes Printer (optional) Waveform: 2-channel Print width: 48mm Paper speed: 25mm/s, 50mm/s EtCO2(optional) Method: Sidestream or Mainstream Measurement Range for CO2: 0...
Accuracy: ±2bpm or ±2%, whichever is greater. 3) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever...
Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~ +2.0 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecifie...
- Accuracy: CO2 concentration - Apnea alarm: YES IBP - Channel: 2 channels - Pressure transducer: Sensitivity: 5( mV/V/mmHg) - Transducer sites: ART, PA, CVP, RAP, LAP, ICP - Alarm range: -10~300mmHg Standard six parameters ECG,SPO2,RESP,TEMP,NIBP,...
Cuff pressure accuracy: ±3 mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg Spo2 Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: un...