In order to obtain the experimental basis for the cause of the previously reported intensity decrease of the 1080 cm-1 band in the presence of NaCl, FT-Raman spectra were measured with 1064 nm excitation for aqueous dispersions of hog kidney mitochondrial outer membrane preparations in phosp...
Ultrananocrystalline diamond (UNCD, ⪅5 nm) has the smallest grain size so far and seems to be well suited for MEMS (micro-electromechanical systems) applications [5]. Besides microscopic techniques, such as SEM, TEM, or AFM, Raman spectroscopy has become the standard tool for the ...
Raman spectroscopy has been applied to the identification of chemical and crystal structural impurities on the surfaces of YBa2Cu3O7−δ (YBCO) films. Th... HCYCK Chu - 《Physica C Superconductivity》 被引量: 7发表: 1998年 Low frequency (1/f) noise in YBa 2 Cu 3 O 7-δ grain boun...
1.3:0.7:1-cells with active layer thickness of 130 nm and 320 nm, simulated by transfer matrix formalism.dSimulatedJSCversus active layer thickness based on constant IQE, with the red stars representJSCcalculated from experimental IQE; the dashed line and patterned areas are guides to the ...
Photonics,C2909)com-bined with a polychromator(Chromex,500IS/MS)to measure the time and wavelength profiles of the SC. Figures1(a)and1(c)show typical spectral profiles of the SC.Many sidebands are observed beside the 532nm seed wavelength,as a result of the stimu-lated Raman ...
In tin oxide nanostructures, oxygen vacancies (OVs) usually determine optical properties and thus exact identification of both OV concentration and type is crucial to exploration of more applications. Currently, the 755–778 cm−1 Raman mode is frequently observed and arbitrarily attributed to Eu (...
Slewing Speed:>100nm/second Stray Light:<10-9 Slits:Standard Set includes; 0.125mm, 0.15mm, 0.30mm, 0.6mm, 1.2mm and 2.4mm x 4.0mm. For other sizes, consult SP. Gratings:Two or four gratings (30 x 30mm) must be purchased.
± 0.6nm (Subtractive) Slewing Speed> 100nm/s Stray Light<10-9 SlitsStandard set includes: 0.125mm, 0.15mm, 0.3mm, 0.6mm, 1.2mm, and 2.4mm x 4.0mm. For other sizes, please consult us Max Resolution< 0.5nm (Additive) < 1nm (Subtractive) ...
25. The Raman fraction fR was set at 0.18, with the Raman response parameters τ1 and τ2 being 12.2 and 32 fs, respectively25. The mode-field diameter was assumed to be 10.8 μm at 2100 nm. A Gaussian pulse with a FWHM duration of 260 fs was used as input with a pulse energy ...
2,2′-Dipyridyl-2-benzothiazolylhydrazone (DPBH) reacts with cobalt(II) to form a 1:3 (metal:ligand) complex having an absorption maximum at 530 nm in weakly acidic to alkaline media. The complex, once formed; remains stable even when it... RB Singh,T Odashima,H Ishii - 《Analyst...