Groll, P. Terdtoon, Closed loop pulsating heat pipes - Part A: Parametric experimental investigations, Appl. Therm. Eng. 23 (2003) 2009-2020, http://dx.doi.org/10.1016/S1359-4311(03)00159-5.Piyanun Charoensawan,Sameer Khandekar,Manfred Groll,Pradit Terdtoon.  Closed loop pulsating ...
Miniature High Heat Flux Heat Pipes for Cooling of Electronics (2000) T. Wong, B. Tong, S. Lim, K. Ooi, Theoretical modeling of pulsating heat pipe, in: Proceedings of 11th Interantional... G. Swanepoel, A. Taylor, R. Dobson, Theoretical modeling of pulsating heat pipes, in: Proceedi...
求翻译:The tube of Closed loop pulsating heat pipe is first evacuated and then filled partially with a working fluid是什么意思?待解决 悬赏分:1 - 离问题结束还有 The tube of Closed loop pulsating heat pipe is first evacuated and then filled partially with a working fluid问题补充:匿名 2013-05...
3) pulsating heat pipe 振荡热管 1. Experimental study onpulsating heat pipewith different working fulids 不同工质振荡热管的传热性能 2. Flow visualization of micro/minipulsating heat pipes 微小型振荡热管的流动可视化实验 3. By study of flow of loopedpulsating heat pipeand by observing s table flow...
3.By study of flow of looped pulsating heat pipe and by observing s table flow character of working fluid and typical phenomena in PHP and by analyz ing the relations between heat transfer rate and heating power,relative position of heating end and cooling end etc some phenomena and problem ...
Effect of working fluids on thermal characteristic of a closed-loop pulsating heat pipe heat exchanger: A case of three heat dissipating devices The closed-loop pulsating heat pipe (CLPHP) is a heat exchanger with a very high thermal conductivity. A single CLPHP is frequently used to release ...
Closed-loop pulsating heat pipe Applied Thermal Engineering Volume 21, Issue 18,December 2001, Pages 1845-1862 Purchase options CorporateFor R&D professionals working in corporate organizations. Academic and personalFor academic or personal use only. ...
Closed loop pulsating heat pipeHeat transferVapor–liquid phase transitionIn this paper, an experimental study is presented on the thermal resistance characteristics of closed loop pulsating heat pipes (CLPHPs) with methanol-based binary mixtures. The working fluids were methanol mixed with deionized ...
Experimental investigation of the effect of using closed-loop pulsating heat pipe on the performance of a flat plate solar collector In this study, performance of a flat plate solar collector operating in conjunction with a closed-loop pulsating heat pipe is investigated experimentally. ... H.,Kar...