The connection to the external heat reservoirs of hot, chilled and cooling water is done by lumped and distributed UA-values for the main heat exchangers... J Albers,G Nurzia,F Ziegler - Esinternational Conference on Energy Sustainability 被引量: 0发表: 2009年 Life Cycle Cost Analysis to Va...
A direct-type cooling tower water chilling water machine set cascade connection tandem natural cooling capacity using system comprises a chilled water pump, a chilled water circulating pipeline, a tail end device, a chilled water machine seat, and a closing-type cooling tower, wherein the chilled...
Taking the project as a study object,calculates the year-round 8760 hours cooling and heating loads of this building,and discusses the load-flow character of water system with two or more surface air handling units in parallel connection.Combined with water pump selecting and energy calculating sof...
The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve. 7.Hydraulic circuit built with galvanized pipe, complete with water discharge connection for shell and tube heat exchanger and flange type hydraulic connectors. 8.Electric panel con...
Water Resistance (Kpa) 2.3 2.8 3.5 3.9 5.8 7.0 8.3 Air Resistance (Pa) 80 Water Connection Pipe 2" Heated by Steam 2 Rows Heating Capacity (KW) 55.1 74.5 93.6 140.4 187.2 234.0 280.7 Steam Pressure (Mpa) 0.2 Steam Temperature (ºC) 115 Air Resistance (Pa) 55 Water Connection...
aA chiller plant which produces chilled water for airconditioning, or an industrial process and which is comprised of chillers, cooling fluid pumps, and cooling towers with electrical motor drives uses a substantial amount of energy. 生产的一棵更加寒冷的植物使水为空调或者包括致冷物、冷却液泵浦和冷...
4. A reducing valve must be installed if the inlet water pressure exceeds 0.7 MPa. Unit: mm 5. All pipes should be wrapped with thermal insulation foam. 4.2 Connecting the DrainpipeBoth hoses and rigid pipes can be connected. This section uses rigid pipe connection as an example. 4 C...
Materials Required for Connecting Chilled Water Pipes Chilled water pipes can be connected as shown in Figure 3-1. Figure 3-1 Chilled water pipes connection (1) Screw thread copper pipe (2) Screw thread steel pipe Component 1 is a port on the equipment. Component 2 needs engineering ...
Model Cooling Capacity W@25ºC Temperature Range Temperature Stability Max Flow Max Pressure Reservoir Cooling water connection Freezing water connection Overall Dimension W*D*H 50/60Hz ºC ºC L/min Bar L mm sL02 5.6/6.6 5-35ºC ±0.1ºC 50 3.6 60 Rp 1 Rp 3/4 380×635...
Water heat exchanger - Brazed plate heat exchanger Water pump (optional) - Wilo/Shinhoo Water connection Inlet&Outlet inch 1-1/2'' 1-1/2'' 1-1/2'' 2'' Noise level dB(A) 65 65 67 71 Net dimension (W*D*H) mm 1432*742*1064 1432*742*1064 1432*742*1064 2000*950...