By the model, it calculates the energy consumption under the different flux ratio, the result shows that the optimal water parameter is different from the design parameter, it has relation with the chilled water pump head. When the pump head value is larger, adopting the smaller design flux's...
In this paper,the author optimizes calculation for air-conditioning chilled water system with largest temperature difference,with the unit of total energy consumption quantity of air-conditioning system for target function.He puts forward the best temperature difference for energy-efficient is 7.2 ℃,an...
The utility model relates to the technical field of a CHW(chilled water) temperature energy-saving control device for central water chillers, in particular to the central water chillers. The control device comprises a CHW host and a controller with the treatment functions of calculation and comparis...
FusionCol8000-C In-room Chilled Water SmartCooling Product (V500R023C10)Modbus Protocol 3 Terms 3 Terms Master node: the NMS, runs on the dedicated back-end server and is responsible for communication with slave nodes. Slave node: Smart Cooling Product...
allocation, specific plug loads and schedules, and calculation details on how to account for energy used from the campus hot and chilled water supply. The... Pless,Shanti,Torcellini,... - 《Ashrae Transactions》 被引量: 16发表: 2011年 EFFICIENT AND RELIABLE OPERATION OF AIR-SIDE ECONOMIZERS...
9.Selective calculation of adjustive valve frozen water system in air-conditioner空调冷冻水系统压差调节阀的选择计算 10.Field Study of Microbial Contamination in Central Air Conditioning Cooling Systems集中空调循环冷却水系统微生物污染实态调查 11.The Application of Water Thermal and Cooling Storage Central...
1.Simulation Study on Heat Transfer Properties of Air-conditioning Chilled Water Systems with Variable Water Volume;变水量空调冷冻水系统换热特性的仿真研究 2.Study on Optimal Control Strategies of VWV Chilled Water System in Building;楼宇空调变水量冷冻水系统的优化控制 3.Selective calculation of adjustiv...
Consumption of ambient warm (17°–31°C) vs. ice-chilled (0°–1°C) drinking water was compared in a within-subjects cross-over trial using nine mature pony stallions housed in tie-stalls during hot summer weather (15°–29°C). Ponies drank similar quantities whether provided warm water...
When multiple units work cooperatively, the controller optimally distributes the heat load to reduce energy consumption and provides backup to improve reliability. Backup: When a unit in the group is faulty, the backup unit starts to operate automatically, improving system reliability. Rotation: Each...
NetCol5000-C In-row Chilled Water-Cooled Smart Cooling Product 2 Commissioning the Smart Cooling Commissioning Maintenance Guide Product Figure 2-33 Setting the method for calculation smart cooling product the supply air temperature Step 3 Press or to select a method for calculation smart cooling ...