Chemical-shift imaging is a lipid-sensitive magnetic resonance imaging (MRI) technique that exploits the resonance frequency differences of fat and water. From: Clinical Imaging, 2016 About this pageSet alert Also in subject areas: Chemistry Immunology and Microbiology Materials ScienceShow moreDiscover...
Egyptian Journal of Radiology & Nuclear MedicineZidan DZ, Habib LA, Chalabi NA. Quantitative chemical-shift MR imaging cutoff value: benign versus malignant vertebral compression: initial experience. Egypt J Radiol Nucl Med 2014; 45:779-786
Pediatric RadiologyOlivier Brissaud,Jean-François Chateil,Martine Bordessoules,Muriel Brun.Chemical shift imaging and localised magnetic resonance spectroscopy in full-term asphyxiated neonates[J]. Pediatric Radiology .2005(10)Cheong JL, Chateil JF, Bordessoules M, et ai. Chemical shift imaging ...
Steeper gradient may be employed to reduce the chemical shift offset in mm. Another strategy is to employ specialized pulse sequences such as fat saturation or inversion recovery imaging. Fat suppression techniques eliminate chemical shift artifacts caused by the lack of fat signal. See also Black...
1H MR Spectroscopy and Chemical Shift Imaging of the In Vivo Brain at 7 Tesla Sunday, 26 November 2006bytobias-lib.uni-tuebingen.de MRI Resources Mobile MRI-Implant and Prosthesis pool-Cochlear Implant-MRI Reimbursement-NMR-Resources 1 - 5(of 12)next ...
MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST). Proc Natl Acad Sci U S A. 2007;104(11):4359-4364. Lu D, Ji Y, Sundaram P, et al. Alkaline brain pH shift in rodent lithium-pilocarpine model of epilepsy with chronic seizures. Brain ...
chemical-shift artifacts; musculoskeletal MRI; finger joints; arthritis Abstract Purpose To study the use of an interleaved water-fat (IWF) sequence with a custom-made radiofrequency (RF) coil for high-resolution imaging of arthritic finger joints. Materials and Methods High-resolution finger magnetic...
Thymic hyperplasia and thymus gland tumors: differentiation with chemical shift MR imaging. Radiology. 2007;243:869–76. doi:10.1148/radiol.2433060797. Article PubMed Google Scholar Priola AM, Priola SM, Cardinale L, Cataldi A, Fava C. The anterior mediastinum: diseases. Radiol Med (Torino)....
The spectra of 2D chemical shift imaging was named the "EDGE" of (CSI)40 were observed using Tth2eanpudlsDe from the imaging of sequences in Fig. S7. The parameters were as follows: spectral width of 14,098 Hz and acquisition time of 0.29 s. Spectral data were processed using...
- 《Investigative Radiology》 被引量: 75发表: 1993年 Glomerular hemodynamics before and after release of 24-hour bilateral ureteral obstruction capillary pressure (PG), intratubular pressure (PT), and pressure in the first order peritubular capillaries (EAP) were measured with a servo-nulling ......