thermodilution and transesophageal Doppler echocardiography.6 horses (3 Thoroughbreds, 3 crossbreeds).Cardiac output was measured in 6 anesthetized horses as lithium dilution cardiac output (LiDCO), thermodilution cardiac output (TDCO), and transesophageal Doppler echocardiographic cardiac output (DopplerCO...
The pump function of heart --- cardiac output (CO) and stroke volume (SV) were measured in20 athletes with arrhythmia and 10 athletes without arrhythmia at... 张宝慧,高云秋,韩霖,刘少玲,王庆全 - 《中国运动医学杂志》 被引量: 0发表: 0年 Cardiac output during submaximal and maximal exercise...
Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery. J Anesth. 2015;29(3):416–20. CentralCheung H, Dong Q, Dong R, Yu B. Correlation of cardiac output measured by...
Cardiac outputwas measured by thermo dilution. 用热稀释法测定心输出量. 互联网 The two kidneys a combined weight of some 300 g in man of thecardiac output. 人的两肾重约300克,而血供量却为心输出量的四分之一. 互联网 AIM : To investigate and develop a new noninvasive measurement method of...
Distribution of cardiac output = =was measured in unanesthetized fetal (n 6) and newborn (n 7) sheep, using the radioactive microsphere technique. Paco, rose from 44 to 70 (fetus) and 38 to 60 torr (newborn) with the addition of CO2 to room air. In the fetus, there were ...
patients and methods : In 30 subjects (17 men, 13 women, aged 50 ± 14 [mean ± SD] years), cardiac output was measured in close temporal proximity by thermodilution as well as Fick or indocyanine green dye, after which the presence and severity of tricuspid regurgitation were assessed by...
Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardiac output was measured in steady-state conditions. The pacemaker was then reprogrammed to the VVI mode at a rate 5 to 10 beats above...
Cardiac output (measured as pulmonary blood flow) was obtained using the thermodilution technique (Cardiac Index Computer SP1435, Gould-Statham, Oxnard. CA); three injections of cold saline were performed over a 30-s period and the mean was calculated. Calculations of TPVR were computed using ...
The cardiac output in male subjects as measured by the technique of right atrial catheterization. Normal values with observations on the effect of anxiety and tilting: Stead, E. A., Jr., Warren, J. V., Merrill, A. J., and Brannon, E. S.: J. Clin. Investigation 24: 326, 1945Show...
How It’s Measured Your cardiac output is your heartbeats per minute multiplied by the amount of blood pumped with each beat. Your doctor can measure it in lots of ways. Pulmonary artery catheter. Your doctor inserts this device into thearterythat sends blood to thelungsto pick up oxygen. ...