进行BD文件validata design时候,报错: [BD 41-237] Bus Interface property FREQ_HZ does not match between /DMA_AXIS_MM2S(100000000) and /axi_dma_0/M_AXIS_MM2S(200000000) 如图所示,自己定义了一个扩展接口DMA_AXIS_MM2S,该扩展接口默认的频率是1... ...
进行BD文件validata design时候,报错: [BD 41-237] Bus Interface property FREQ_HZ does not match between /DMA_AXIS_MM2S(100000000) and /axi_dma_0/M_AXIS_MM2S(200000000) 如图所示,自己定义了一个扩展接口DMA_AXIS_MM2S,该扩展接口默认的频率是1... ...
ERROR [BD 41-237] Bus Interface property FREQ_HZ does not match between /mig_7series/S_AXI(166250000) and interconnect_1/s00_couplers/M_AXI(10000000) How can I fix this issue? Solution If an AXI interface is made external, the FREQ_HZ property will default to 100MHz. ...
[BD 41-237] Bus Interface property CLK_DOMAIN does not match between /microblaze_0_axi_periph/xbar/S01_AXI(kintex7_pcie_design_clk_wiz_1_0_clk_out1) and /axi_pcie_0/M_AXI(kintex7_pcie_design_axi_pcie_0_0_axi_aclk_out) [BD 41-237] Bus Interface property FREQ_HZ ...
这是因为设计的模块接口里有clock(时钟)输出,但是没有特别指定相关FREQ参数,因此在与其它IP连接后,会报一个Warning。 解决方法: 原来的写法: output bram_port_b_clk; 参考官方模组的写法修改如下: (* X_INTERFACE_INFO = "xilinx.com:signal:clock:1.0 CLK.CLK CLK" *) (* X_INTERFACE_PARAMETER = "XIL...
I (746) cpu_start: cpu freq: 160000000 Hz I (746) cpu_start: Application information: I (749) cpu_start: Project name: human_face_detection_lcd I (755) cpu_start: App version: v0.9.4-181-gd3aa39b-dirty I (762) cpu_start: Compile time: Feb 13 2024 22:01:03 ...
A host controller can access internal resources via the DSI interface to the local bus. When you design a new system based on the MSC8122/26, it is useful to understand the interaction of the local bus masters and their interaction with the device memory structure. The programmable priority ...
1.0 3 – SCIx — Two serial communications interface modules with optional 13-bit break. Full duplex non-return to zero (NRZ); LIN master extended break generation; LIN slave extended break detection; wake on active edge – IIC — One IIC; up to 100 kbps with maximum bus loading; multi-...
Using the PWM control interface, the TPS61195 integrates a high-speed, high-precision digital counter to calculate the PWM duty cycle on the PWM pin. The PWM duty cycle digital counter auto-adjusts the sample rate for a 200Hz to 20 kHz PWM input signal. The key benefit of the digital ...
(FM+) Compatible I2C Bus Interface With 30 mA High Drive Capability on SDA Output for Driving High Capacitive Buses • Internal Power-On Reset • Noise Filter on SCL/SDA Inputs • No Glitch on Power Up • Active-Low Reset (RESET) • Supports Hot Insertion 1 2 Applications • ...