B2 Biological Safety Cabinet has higher class of safety protection compared with type A2, it may be used for work with volatile toxic chemicals and radionuclides as required as adjuncts to microbiological studies. Features: 1. Motorized Front Window. 2. Time Reserve Function. 3. ...
LabGard® Class II Type B2 Biological Safety Cabinets feature downflow air drawn from within the laboratory or outside air. No downflow air is drawn from the cabinet exhaust air. All downflow and inflow air is exhausted through a HEPA filter without recirculation within the cabinet.NuAire, Inc...
Class II B2 Biosafety Cabinet PRO Series External Size (W*D*H)mm 1100*750*2250mm Internal Size (W*D*H)mm 940*600*660 mm Max Opening 420mm Front Window Motorized,two-layer laminated toughened glass ≥ 6mm,anti UV. Noise ≤ 67 dB Illumination ≥1000Lux Material Working area: 304 stainl...
Class II biological safety cabinet; Vertical laminar negative pressure model, air flow mode: 100% discharge, 0 cycle requirement. High security Negative pressure design ensures the safety of operators; Integrated sliding safety door positioning, easy to operate; Equipped with filter ...
Class II Type B2 Class II Type B2, NuAire Biological Safety Cabinets provide personnel, product and/or environmental protection. Ergonomic Biosafety Cabinet design improves laboratory safety practices and process accuracy. 2 results NU-560 LabGard TE (Total Exhaust) NU-560 Class II, Type B2 Biosafet...
Biosafety Cabinet Cleanliness ISO Class 4 Filter Level ULPA:≥99.9995%,@0.12μm Downwinds 0.33±0.025m/s Flow of Wind 0.53±0.025m/s Noise ≤65dB Vibration ≤5μm(rms) Power Supply AC220V/50HZ Biosafety Personal Protection All Impact samplesCFU≤10,Slit sampler CFU≤5 Product Protection All ...
类型 ISO5(100级Class100)/I 型号 BHC-1000IIA2 型号 Model BSC-1300ⅡA2 Ⅱ级A2型生物安全柜 Class Ⅱ Type A2 Biosafety Cabinet BSC-1300ⅡB2 Ⅱ级B2型生物安全柜 Class Ⅱ Type B2 Biosafety Cabinet 空气洁净度 Clean Grade HEPA:ISO 5级(100级Class100) ULPA:ISO 4级(10级Class10) HEPA:ISO ...
Unlike other Class II cabinets, the Type B2 model relies heavily on external infrastructure for proper function. It does not operate autonomously but requires integration with an external exhaust blower. This external blower is essential for maintaining the cabinet's functionality, as it pulls the in...
Laboratory Class II Biosafety cabinet B2 Biological Safety Cabinet Product characteristics: Air curtain type isolation design to prevent internal and external cross-contamination,30% air exhaust,70%air re-circulation,negative pressure vertical flow. Moving thr front window up an...
Model NO. BSC-110B2 Certification CE Usage Research Institute, Hospital, School, Company Noise ≤62DB Type Vertical Flow Clean Bench Product Name Biosafety Cabinet Purification Grade Class 100(Federal Standard 209e Front Inlet Wind Speed 0.55±0.025m/S Air Tighteness ≤10-6L/S(at 500...