Instrumented axial load tests are performed to verify the pile design and to provide valuable information to permit an economically feasible redesign. Bi-directional static load test (BDSLT or O-cell test), an innovative load test method, performed simultaneously in two directions; adopting ...
Welcome to YJACK Technology, your Bi-Directional Pile Load Testing Specialist Worldwide. Specializing in bi-directional pile load tests, we ensure the integrity and performance of foundation piles through innovative testing methods. Our comprehensive ser
Our first ever bi-directional load test was completed for a condominium project at Bandar Sunway in Petaling Jaya. 2012 Our biggest bi-directional test thus far for a Ø2,200mm bored pile (6,650 tonnes) with a depth of bored 77m was completed for a 55 storey residential tower at KLCC...
The bi-directional load test was performed in two separate stages with the aid of a special hydraulic cylinder whose diameter is equal to that of the pile shaft. In the first stage, the hydraulic cylinder is assembled immediately above the bottom helix plate, and the end bearing capacity of ...
The increasing use of bi-directional (Osterberg cell) load tests in piles necessitates a reliable evaluation of the load-movement relationship equivalent to the head-down load test. In this study, the existing evaluation methods were reviewed, and a new method for evaluating the equivalent head-...
The damage of RC shear wall due to the bi-directional horizontal loading was observed from this earthquakes. In general, the RC shear walls are designed to resist the horizontal load in the direction of the principal axis. This design method can be used to ensure the design strength based ...
The apparatus for bi-directional pile load test and the method of bi-directional pile load test therewith PURPOSE: An apparatus and a method for a bidirectional pile load test are provided to prevent the eccentricity of a pile because upper and lower plates are moved vertically by a reinforcing...
Bi-Directional Pseudodynamic Test of a Full-Size Three Storey Steel Concrete Building with Rigid and Semirigid Joints Molina F.J., Verzeletti G., Magonette G., Buchet Ph., Gerardin M. Bi-directional pseudodynamic test of a full-size three-storey building. Earthquake Engineering and Structural...
The test system is equipped with inline conductivity probes for continuous monitoring of concentration. Along with the converter, the deionization system is ... A Omosebi,G Xin,J Landon,... 被引量: 0发表: 2014年 加载更多研究点推荐 interfacing test system channel Bi-directional buffer ...
In this presentation, we go through the HEV/EV market status and history, OBC specifications, technology trends, topology selections and design considerations of an OBC system. Complete test results of a 6.6kW OBC reference design will be shown to demonstrate the performance of our...