Recently, concrete-filled multicellular steel tube (CF-MCST) walls are being widely used in China. This paper presents a theoretical and numerical study on the moment capacity of a beam-to-wall connection in which an endplate and two side-plates grip the wall-end by welding, and then the ...
Quasi-static tests of rigid joint between steel beam and concrete wall in high-rise mixed structures; 混合结构中钢梁与混凝土墙刚性节点的拟静力试验补充资料:混凝土防渗墙 在松散透水地基中连续造孔,以泥浆固壁,往孔内灌注混凝土而建成的墙形防渗建筑物。它是对闸坝等水工建筑物在松散透水地基中进行垂直防...
关键词:混合结构;钢梁混凝土墙节点;嵌固弯矩;螺栓连接 中图分类号:TU973 14TU973 257文献标识码:A AnaIysisofpartiaIIyrestrainedmomentatboItedconnectionjointof steeIbeamtoconcretewaII YELieping 1 ,ZHENGCongIi 1 ,CA Yiyan 2 ,YUYin uan 2 (1.DepartmentofCiviIEngineering,TsinghuaUniversity,Beijing100084,Ch...
The paper mainly introduces design points of concrete wall and its off-plate beam,describes structural design matters from aspects of model simplification,concrete wall design and structural demands,and analyzes project cases,which has provided some guidance for designers to solve similar problems in fut...
The calculation methods of tensile and shear strength of headed studs embedded in the concrete are summarized.The analysis of the headed stud embedded at the pinned joint of steel beam to concrete wall under external moment and shear forces is discussed.Compared with 29 test results available,the...
PURPOSE: To obviate bar arrangement works for beam connection reinforcing bars at a construction site and enhance the efficiency in executing construction works by placing each beam connection bar protruding at the end of one beam concrete form upon the step face of another beam concrete form, and...
In construction of steel buildings, the Beam-to-Column connection is one of the most important component in it. The structural design of Non-Scallop forms have improve the mechanical properties than a beam with normal scallop forms. Otherwise the technique of welding robot has completed in flat ...
The SCBB performed very well and exhibited almost identical behavior to the traditional high strength slip-critical bolts [20]. However, the reinforced concrete slab at the top beam flange was not considered in these tests. Moreover, the performance of SCBBs at connection regions was ...
a\\The hepatic stress protein (hsp70) response to interacting abiotic parameters in fish exposed to various levels of pollution 正在翻译,请等待...[translate] aThe attached drawing is a section detail of a tilt-up concrete wall panel and beam junction, at a scale of 1:10. It shows the mai...
An innovative joint connecting beam for precast concrete shear wall structures The precast shear wall structure has outstanding f Wang,Dun,Lu,... - 《Structural Concrete Journal of the Fib》 被引量: 0发表: 2016年 BEHAVIOUR AND DESIGN OF BEAM COLUMN CONNECTION PRECAST CONCRETE FOR A SEISMIC RESI...