[15].[结构][分析][ETABS] ETABS V9中的楼层质量 [16].[ETABS] ETABS2016剪力墙网格划分尺寸 (Auto Rectangular Mesh Setting for Walls) [17].[ETABS][组合截面] ETABS中通过截面设计器定义的组合截面 (ETABS v9 and ETABS 201x) (ETABS Section Designer) [18].[ETABS] ETABS警告”THE STRUCTURE IS UN...
Dynamic Analysis of RC Frame in Relation to the Storey Drift and Lateral Displacements, Base Shear Using Software ETABSINTRODUCTION:1.1 Overview:Many multistorey buildings in India today have open first storey as an unavoidable feature. This is primarily being adopted to accommodate parking or ...
摘要: In the present paper, nonlinear time history and response spectrum analyses were carried out using Etabs-2015 software to study the influence of soil condition beneath the isolated base. The effects...关键词: Isolated base (IB) Fixed base (FB) Time history analysis Response spectrum (RS...
介绍了隔震结构弹塑性动力分析程序HBTA2 0的编制原理及功能 ,通过与实验室模型试验及ETABS程序计算结果的对比 ,证明用HBTA2 0程序进行动力分析的可靠性。 2. By discussing the vibration characteristics on the equivalent model of shear type multi degree of freedom base isolated structure, the sliding oscillati...
3D-BASIS-TABS has three options for modeling the elastic superstructure: (1) three dimensional shear building representation; (2) full three dimensional representation; and (3) three dimensional building representation via a stiffness matrix supplied by user. The report describes the development and ...
It was observed that t he variation in maximum displacement of stories in base isolated model is very low while compared with fixed base model. It was also observed that storey overturning moment & stor ey shear are also found to be reduced in base isola ted building.S. Dhawade...
The seismic analysis is carried out using ETABS software to determine nodal displacement, storey drift and storey shear etc. The modal analysis is also carried out to determine its natural frequencies and mode shapes. Further, the paper deals with base isolation of building for hard & soft soil...
Objectives of the WorkTo compare the response of the building such as Timeperiod, Base shear, Acceleration and Bottom displacement,for 10 storied RC regular building with and without baseisolation by considering the Response Spectrum Analysisusing Etabs-2013. structure, dynamic analysis should be ...
The Response quantities are mode period, Base shear, Storey displacement and storey acceleration.Based on analysis results, time history shows better performance both in Base shear and acceleration. Regular plan building increase base shear and acceleration using HDRB compared with irregular building for...
isolation model, after using the optimum Parameters proved that the parameters of base isolation system determined by genetic algorithm are true optima and effective not only in the objective function of optimization, but also on others dynamic response such as displacement, drift, and base shear.doi...