Clearly, balloon angioplasty has come of age. The information regarding survival and reintervention was very useful. What was surprising about this report was that there was no mention of the primary surgical approach for valvar aortic stenosis. The primary surgical approach was also not mentioned ...
Non-deflating angioplasty balloonPCI complicationsTAVRValve in valveDescribed is a complication of rescue left main coronary stenting due to threatened left main closure following a "valve in valve" TAVR procedure. Left main stent post dilatation with a NC Trek balloon was complicated by a failure ...
Acute complications and restenosis in the first few months after a successful procedure remain the two major limitations of coronary balloon angioplasty. New devices have been developed in order to avoid these limitations. We tested the directional atherectomy catheter clinically and compared the immedi...
balloon catheter(balloon-tip catheter) a catheter with a balloon at the tip that may be inflated or deflated while the catheter is in place to create, enlarge, or occlude a passageway; see alsoballoonangioplasty. The pressure-sensitive balloon may be used to facilitatehemodynamic monitoring. ...
Percutaneous transluminal angioplasty was first proposed and performed by Dr. Charles Dotter and his colleagues over 25 years ago.
Pre-dilatation of Severely Stenotic Aortic Valves Using Angioplasty Balloons Prior to Balloon Aortic Valvuloplasty Balloon aortic valvuloplasty (BAV) for severe, senile aortic stenosis (AS) is enjoying a renaissance in inter-ventional cardiology both as a bridging treat... MZ Khawaja,M Thomas,S Red...
Intramural haematoma secondary to balloon angioplasty.Panels A&B: Initial angiography and IVUS examination confirmed ostial LAD disease.Panel C: Post procedure angiography showed a good angiographic result in the LAD.Panel D: IVUS examination of the Cx revealed no evidence of dissection.Panels E&F:...
Between September 1985 and April 1987, 110 consecutive patients who had successful coronary angioplasty were included in a randomised prospective controlle... P Urban,N Buller,K Fox,... - 《British Heart Journal》 被引量: 3021发表: 1989年 Evaluation of a behavioral measure of risk taking: the...
A new intraaortic balloon catheter is described in this paper. The balloon is a standard single chamber type and its volume is 35cc. The length of balloon ... Y Yoshioka,N Tsutsui - 《Jinko Zoki》 被引量: 3发表: 1995年 Guide catheter system for an angioplasty balloon catheter The present...
Transverse aortic wall tears in infants after balloon angioplasty for aortic valve stenosis: relation of aortic wall damage to diameter of inflated angiopl... Aortic wall tears resulting from rupture of dilating balloons in infants undergoing transluminal balloon angioplasty have not been previously recog...