We need to be aware that 6 gauge wire amps and watts depend on two additional factors, in addition to the gauge factor (which determines the diameter of a wire). These two factors are: Wire material. We have to differentiate between 6 gauge copper and 6 gauge aluminum wire. Example: Med...
型号 F75-6-M Ferrule Type NA Insulation Material Non-Insulated Maximum Copper Conductor Size (AWG) NA Minimum Copper Conductor Size (AWG) NA Flammability Rating NA Wire Strip Length (mm) 6 Wire Strip Length (In.) 0.24 Insulation Type NA Inside Diameter (In.) 0.04 Inside Diameter (mm) 1....
Size Class K Copper Strand Qty/AWG Class K Copper Strand Style Nominal Conductor Outside Diameter Insulation Thickness Minimum Finished Outeside diameter 18 AWG 16/30 Tinned 0.047" 0.030" 0.105" 16 AWG 26/30 Tinned 0.059" 0.030" 0.118" 14 AWG 41/30 Tinned 0.074" ...
-- 14.732 13.119 11.684 10.404 9.266 8.252 7.348 6.544 5.827 5.189 4.621 4.115 3.665 3.264 2.906 2.588 2.305 2.053 1.828 1.628 1.450 1.291 1.150 1.024 0.912 0.812 0.723 0.644 0.573 0.511 0.455 0.405 常用线规号码与线径对照表...
Applied to reinforced core of aluminum stranded wire and aluminum clad steel wire of all aluminum clad steel strand. Aluminum-Clad steel wire Nominal Diameter Area Min Tensile Strength Calculated Breaking Load Min Coating Thickness Max D.C Resistance at 2...
SIZE OF CONDUCTOR No.&Nominal Diameter of Wire Wall Thickness Approximate Overall Diameter Minimum Insulation Resistance Ampacity Cable Nominal Weight MM Approximate AWG MM MM MM MM M-Ohm-Km 90ºC Wet 90ºC Dry KG/KM Solid PVC Nylon THWN THHN 1.6 14 1×1...
¤4) Single wire diameter : 0.08mm ¤5) Nominal Voltage : 600 V ¤6) Test Voltage : 2000 V ¤7) Colors : Black ; Red ; White ; Blue ; Yellow; Green;Brown,Green/Yellow ¤8) Our silicone wire are widely u...
Diameter of conductor Min. No of wire Insulation Thickness Jacket Thickness Dia Approx. Wt. NEC / / / mm n mm mm mm Kg/km Amp 2.08 14 AWG 1.85 7 0.38 0.1 2.8 25 20 3.31 12 AWG 2.32 7 0.38 0.1 3.3 37 25 5.26 10 AWG 2.95 7 0...
Dimensions - conductor cross-section Construction of individual conductor External diameter Insulation thickness Conductor resistance at 20 °C Specific. el. resistance of insulation at 70°C Cu weight Cable weight Packing* nominal min-max. nominal max...
Characteristics of tin plated copper wire DiameterToleranceOvality maxThickness of CoatingElongationTensile StrengthMin. Bend PropertyElectricresistivty Soft wireSemi hard wireHard wireSoft wireSemi hard wireHard wireWeighttimes mmmmmmµm%kg/mm2gΩmm2/m ...