As the technology of blood cell analyzers has recently been described in this journal, this article focuses on the strengths and weaknesses of the automated blood cell differential. This allows judgment of the risks of a stepwise approach dependent on the medical discipline sending the sample.C. ...
1971. Automated differential fluorometric analysis of norepinephrine and epinephrine in blood plasma and urine. Biochemical Medicine, 5: 483-504.Fiorica, V. & Moses, R. (1971). Automated differential fluorometric analysis of norepinephrine and epinephrine in blood plasma and urine. Biochemical Medicine...
Total blood and differential leukocyte counts are performed with random access automated cell-counters. The aim of this study was to compare and evaluate the analytical performances of Siemens/Advia-120 and Beckman/Coulter LH-750. Total 163 samples were sequentially counted by Siemens/Advia-120 and...
The total 1 820 patient samples were randomly detected with automated hematology analyzer XE-2100 and blood smear was reviewed including observation of cell morphology and manual WBC differential analysis.Base on hematology review criteria suggested by international consensus group.The true positive ratio(...
The latter method is also useful for differential analysis of free type from protein-bound type compound in body fluid. Free type compound after ultrafiltration will exist in filtrate. Previously ultrafiltration and SPE were carried out off-line and the former was done manually, which was ...
Could the UKNEQAS program "Manual Differential Blood Count" be performed by the use of an automated digital morphology analyzer (Sysmex DI-60)? The wrong recognition of an element as a cell was rare (less than 1%) and it mostly involved smear cells or giant platelet, that were identified ...
Letter to the EditorMarco Rosetti*, Evita Massari, Giovanni Poletti and Romolo M. DorizziCould the UKNEQAS program“Manual DifferentialBlood Count”be performed by the use of anautomated digital morphology analyzer (SysmexDI-60)? A feasibility studyhttps://doi.org/10.1515/cclm-2020-0627Received...
Figure 1. Each side of a two-sided hemocytometer is etched with nine major (1 mm) squares, and each square corresponds to a 0.1 μl volume. For most cell lines, count in the corner squares, but smaller cells such as red blood cells may be counted in the center square using a higher...
This selection also resulted in a discrepancy between capillary and venous blood samples with ratios of 0.70 and 0.3, respectively. In addition, the study did not include a comparison of differential white blood cell counts with manual microscopic evaluation. Although the analytical evaluation of the...
Fully automated machine learning (AutoML) for predictive modeling is becoming a reality, giving rise to a whole new field. We present the basic ideas and principles of Just Add Data Bio (JADBio), an AutoML platform applicable to the low-sample, high-dime