IC-Auto Clave试验的主要特点包括 1.高温:试验温度设定在121°C或更高,以模拟高温环境对IC的影响。 2.高压:试验压力设定在2个大气压(15 psi)或更高,以模拟高压环境对IC的影响。 3.高湿度:由于试验在封闭的PCT试验箱中进行,湿度可达100%相对湿度(Rh),以模拟潮湿环境对IC的影响。 4.自动控制:现代IC-Auto C...
Autoclaving is the method of choice for decontaminating cultures,glassware, and pipettes. Autoclaving for 60–90min at 121°C (15psi), depending on the loading conditions, to achieve a waste temperature of at least 115°C for 20min is recommended. Effective autoclaving will depend on time, te...
shermanii did not grow in autoclave-sterilized cheese whey (121°C, 15 psi, 20 min) at whey concentrations greater than 2% (w/v) spray-dried sweet dairy whey. Propionic acid was produced from autoclave-sterilized whey by growing P. shermanii in mixed culture with Lactobacillus casei . In...
Many autoclaves are used to sterilize equipment and supplies by subjecting them to pressurized saturated steam at 121 °C (250 °F) for around 30-60 minutes at a pressure of 15 psi (103 kPa or 1.02 atm) depending on the size of the load and the contents. The autoclave was invented ...
Displays two selectable temperatures (either 121 or 134 degrees C) and a selection of six preset sterilization programs, including an unwrapped, wrapped, plastic,cotton etc. This model also can setting the sterilization time and drying time. The autoclave features three tr...
Displays two selectable temperatures (either 121 or 134 degrees C) and a selection of six preset sterilization programs, including an unwrapped, wrapped, plastic,cotton etc. This model also can setting the sterilization time and drying time. The autoclave features three trays ...
• Operating Pleasure Range 15 - 30 psi • Digital and Analog pressure display • Temperature Range 121 °C to 134°C • High quality Door GasKet • Safety Feature: Pressure release valve, High Temperature cut-off • Ergonomic ASME Standard Design ...
Prior to the first autoclave run on a given day, a “flash” cycle is run with two prevacuum pulses each with 5 psi steam and 25 in. Hg vacuum, followed by a 5-min sterilization time at 121°C, and a 2-min dry time. This preheats the chamber for subsequent runs. Loads are ...
Indicator turns green from blue under 121 °C (15-20 minutes or 134°C (3-5 minutes, means that the sterilization process fulfills the eligible requirement.3) EO gas sterilization indicator tape: Indicator turns blue or yellow from red under part...
Displays two selectable temperatures (either 121 or 134 degrees C) and a selection of six preset sterilization programs, including an unwrapped, wrapped, plastic,cotton etc. This model also can setting the sterilization time and drying time. The autoclave features three...