between the series winding 2 and the shunt winding 3, an on-load voltage regulator 10 combined with the tap winding 11 and an excited winding 12 is contained in a vessel different from the transformer main body 1 while the main body 1 and the regulator 10 are connected electrically-separa...
5) Tap-changing auto-transformer 自耦调压变压器 例句>> 6) voltage regulating autotransformer 调压自耦变压器 例句>> 补充资料:自耦变压器 原绕组和副绕组间除了有磁的联系外,还有电联系的变压器。比普通变压器节省材料,体积小,占地少,投资和运行费用少,效率也较高。常用于联接不同电压等级的电力系统。据此...
auto-transformer中文翻译 自耦变压器 auto-transformer是什么意思 网络 自耦变压器; 自藕变压器; 自耦合变压器词组短语 1.auto transformer 自耦变压器;自耦变换器 2.auto-transformer starter 自耦变压器起动器;自耦减压起动器;自偶变压起动器 3.Neutral auto-transformer 中性点接地自耦变压器 4.Single-phase auto...
The Auto - transformer Starter employs an auto - transformer to reduce the voltage during the start period. 超动期间自耦变压器起动器使用自耦变压器降低电压. 互联网 The parameters, structure, design difficulty, solution and test data of 900 MVA on - load - tap - changing auto transformer are ...
On-load transformer tap changing system An on-load transformer tap changing system, for example for a power transformer, wherein the secondary or primary of a transformer includes at least one first tap and one second tap. A main connection circuit is used for permanent connec... JP Lavievill...
4) Tap-changing auto-transformer 自耦调压变压器 例句>> 5) voltage regulating autotransformer 调压自耦变压器 例句>> 6) automatic voltage regulator 自动调压器 1. This paper introduces the operating principle of the automatic voltage regulator,and in the light of the problems occurring in the...
An auto-transformer, compared to a separate-winding transformer, is characterized by small impedances, which can even be very small at the neutral tap position. Especially for auto-transformers which have identical voltage levels at both sides, this feature cannot be modeled for load flow ...
14.Connection Comparison of Two Turns in On-Load-Tap-Changing Auto-Transformer有载自耦调压变压器两种线匝连接方式的比较 15.Derivation of Short Circuit Reactance in Tap-Changing Auto-Transformer with Relative Magnetic Leakage Method用相对漏磁链法推导自耦调压变压器短路电抗 16.transformer-coupled pulse am...
The brush track is made by removing a portion of the insulation from each turn of the winding, forming a series of commutator elements. The basic principle is that of a tap-changing transformer. The brush is always in contact with one or more wires and continuously taps off any desired fra...
5.2 Service temperature range of the tap changer in oil is -25ºC ~ +100ºC. 5.3 Vertical inclination of OLTC should not be over 2% when it is mounted onto the transformer. 5.4 OLTC should be operated in the place without heavy dusty and any corrosive or ...