si是国标,pu是采用标幺值
SimPowerSystem block Asynchronous Machine SI Units. Learn more about simulink, simpowersystems, asynchronous machine si units Simscape Electrical
Block 1: 'A_stator: Asynchronous Machine SI Units' Block 2: 'Series RLC Branch2' The first block, modeled as a current source, cannot be connected in series with the inductive element of the second block. Add a high-value resistance in parallel ...
Error evaluating parameter 'Mechanical'... Learn more about error evaluating parameter 'mechanical' in 'model/asynchronous machine si units' caused by: index exceeds array bounds.
matlab中两种异步电机的区别:Asynchronous Machine pu Units和Asynchronous Machine SI Units的区别,急求 虽没用看名称应该单位区别具体要看应帮助
Creating emergency thre 分享16赞 matlab吧 遗忘千年FAN 调压调速系统仿真遇到以下情况,怎么解决 The following two blocks cannot be connected in series because they are modeled as current sources: Block 1: A_rotor: Asynchronous Machine SI Units Block 2: B_rotor: Asynchronous Machine SI Units Add a...
F Combined rotor and load viscous friction coefficient Dialog Box and Parameters You can choose between two Asynchronous Machine blocks to specify the electrical and mechanical parameters of the model, by using the pu Units dialog box or the SI dialog box. Both blocks are modeling the same ...
Error evaluating parameter 'Mechanical'... Learn more about error evaluating parameter 'mechanical' in 'model/asynchronous machine si units' caused by: index exceeds array bounds.