利用胶乳球测定医用面具材料粒子渗透性初始效率的标准试验方法 Standard Test Method for Determining the Initial Efficiency of Materials Used in Medical Face Masks to Penetration by Particulates Using Latex Spheres ASTM F2299-03由美国材料与试验
内容提示: Designation: F2299/F2299M − 03 (Reapproved 2017)Standard Test Method forDetermining the Initial Efficiency of Materials Used inMedical Face Masks to Penetration by Particulates UsingLatex Spheres 1This standard is issued under the f i xed designation F2299/F2299M; the number ...
ASTM F2299/F2299M-24 引用标准 ASTM D1777 ASTM D2905 ASTM D3776/D3776M ASTM F1494 ASTM F2053 ASTM F328 ASTM F50 ASTM F778 适用范围 1.1 本测试方法规定了使用单分散气溶胶测量材料初始颗粒过滤效率的程序。1.1.1 本测试方法利用 0.1 至 5.0 µm 尺寸范围内的光散射粒子计数和 0.5 至 25 cm/...
ASTM F2299 F2299M-03(R 2017) 星级: 8 页 ASTM F29-97(R 2017) 星级: 4 页 (高清正版) ASTM E299-2017 星级: 4 页 (高清正版) ASTM F2028-17 星级: 15 页 (高清正版) ASTM F2129-17b 星级: 9 页 (高清正版) ASTM F2216-17a 星级: 17 页 (高清正版) ASTM F2275-17 星级: ...
ASTMF2299F2299M-03(R2017)用乳胶球测定医用口罩材料被微粒渗透的初始效率的标准试验方法-美国标准.pdf 下载文档 收藏 分享赏 0 内容提供方:便宜高质量专业写作 审核时间:2020-04-27 审核编号:8065034015002110 认证类型:实名认证 能力类型:服务提供商
免费查询更多astm f2299 测试仪详细参数、实时报价、行情走势、优质商品批发/供应信息等,您还可以发布询价信息。
ASTM F2299 F2299M-03R 2017 F2299M 03 2017 《ASTM F2299 F2299M-03(R 2017) .》由会员分享,可在线阅读,更多相关《ASTM F2299 F2299M-03(R 2017) .(8页珍藏版)》请在人人文库网上搜索。温馨提示: 1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE...
免费查询更多ASTM F2299 过滤效率测试仪详细参数、实时报价、行情走势、优质商品批发/供应信息等,您还可以发布询价信息。
PFE(微粒过滤效率)测量口罩过滤亚微米颗粒的效果,期望也能以类似的方式过滤。百分比越高,掩膜效率越好。虽然可以使用0.1到5.0微米的粒度进行测试,但ASTM F2100-19规定使用0.1微米的粒度。在比较测试结果时,重要的是要注意使用的测试粒子的大小,因为使用较大的粒子大小会产生误导的PFE评级。 ASTM F2299 中对0.1微米微粒...
美国医用口罩测试标准ASTM F2100要求0.1微米的颗粒过滤要求不小于95%,测试引用方法ASTM F2299-17,该方法通过在受控的气流室内对单位体积的上游和下游乳胶气溶胶浓度进行采样,来测量医用口罩材料的初始过滤效率。 需要注意的是,F2299测试方法原理上与国标YY 0469近似,但是过程要求却更严格且有不少差异,所以测试结果不具有...