AspenTech can optimize CAPEX and OPEX with heat exchanger design software modeling within the larger process using a comprehensive set of rigorous HX models.
This course focuses on the Aspen EDR which is widely used for heat exchanger design & ratingLearn the fundamentals of producing an optimized shell & tube heat exchanger designDiscover how to accurately rate and simulate existing heat exchangers, thus increasing your understanding of existing equipment ...
aspen exchanger design and rating-换热器设计严格eh.pdf,Heat Exchanger Specification Sheet 1 Company: 2 Location: 3 Service of Unit: Our Reference: 4 Item No.: Your Reference: 5 Date: Rev No.: Job No.: 6 Size 660 / 4000mm Type BEM Hor Connected in 1 paral
AspenExchangerDesignandRatingShell&TubeV9Page1Printed:2018/8/14at21:02:48File:C:\Users\15827\Desktop\选型\换热器选型\E0102xuan.EDRProblemDefinitionDescriptionHeadingCompany:Location:ServiceofUnit:ItemNo.:Date:OurReference:YourReference:JobNo.:
换热器设计exchanger design and rating v9 e0109haspen交换器额定值风冷.pdf,Aspen Exchanger Design and Rating Air Cooled V9 File: G:\换热器\ E0109.edr Printed: 2019/7/14 at 10:31:42 Aircooled Summary 1 Unit Length/Width/Height 8.223 / 2.88 / 0.2078 m Tube l
Aspen Exchanger Design and Rating Shell Tube V9 Page 1 File: C:\Users\15827\Desktop\选型\换热器选型\E0306xuan.EDR Printed: 2018/8/14 at 21:01:06 Problem inition Description Heading Heading Company:Company: Location:Location: Service of Unit: Our Reference:Service of Unit: Our Reference: ...
1、Heat Exchanger Specification Sheet1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556Company: Location:Service of Unit:Our Reference:Item No.:Your Reference:Date:Rev No.:Job No.:Size660/4000mmTypeBEMHorConnected in1parallelSurf/unit(eff.)123mShells 2、/unit1Surf/...
Aspentech.ExchangerDesign.Infrastructure.dll丢失的解决方法 由于找不到Aspentech.ExchangerDesign.Infrastructure.dll 无法继续执行代码 无法启动此程序,因为计算机中丢失Aspentech.ExchangerDesign.Infrastructure.dll,尝试重新安装该程序以解决此问题。 启动Aspentech.ExchangerDesign.Infrastructure.dll 发生错误。无法找到指定的...
EDR suite of thermal design programs Aspen MUSE - Design and performance simulation of multi-stream, plate-fin heat exchangers Aspen Plate Exchanger(formerly Aspen Plate+) - Design, checking, and simulation of plate heat exchangers Aspen Plate Fin Exchanger - Design, simulation and rating of multi...
xp系统安装 aspen v7.2时发现,在可选的安装模块里面没有了edr(exchanger design and rating)模块,但是在安装文件中有edr v7.2的文件夹和相关的安装程序,安装了不知n次,未成功,望高手指点! 展开 0 评论0 举报 病态娇女,工艺专业主任 2018-05-18回答 安装时把那个升级也装了,就变成7.2.1了,就可以了 ...