asp.net core程序在调试时,或者在生产环境运行dotnet命令后,报错:Microsoft.Hosting.Lifetime[0] Application is shutting down... 我这边的原因是:几位大哥写了几个后台任务,继承了BackgroundService,ExecuteAsync方法内使用的代码是同步执行。 也就是说程序要起来,必须等待所有自定义的BackgroundService执行完。 既然...
支持(0) 反对(0) dudu | 园豆:28527 (高人七级) | 2024-01-03 16:59 @dudu: 就是没有任何错误,直接就是Application is shutting down了 支持(0) 反对(0) 显示昵称已被使用了呀 | 园豆:190 (初学一级) | 2024-01-03 17:00 而且是不规律的,有时候隔几分钟,有时候隔十几分钟 支持(0) ...
Jobs of any type fail with the error, “Application is shutting down.” For example: Application is shutting down. Failed to download disk. Shared memory connection was closed. Failed to upload disk. Agent failed to process method {DataTransfer.SyncDisk} ...
Our IIS web server unexpectedly shut down then restarted. The application logs state: Application is shutting down... (90f52c38) Why did this happen and how to fix?Internet Information Services Internet Information Services Microsoft web server software. 1,658 questions Sign in to...
The SDK channel keeps telemetry in buffer and sends it in batches. If the application is shutting down, you might need to explicitly callFlush(). TheFlush()behavior depends on the actualchannelused. Per.NET Core/.NET Framework Console application, explicitly callingFlush()followed by sleep is ...
Application is shutting down... The web server which hosts your web application has started. As you can see, it's listening on port 5000 on your local machine. As such, it's enough to open your browser and point it to https://localhost:5000 to see the website running:...
info: Microsoft.AspNetCore.Hosting.Internal.WebHost[2] Request finished in 44.8464ms 200 image/jpeg Unhandled Exception: System.ObjectDisposedException: The CancellationTokenSource has been disposed. at System.Threading.CancellationToken...
2021.08.07 15:05:30.774584 [ 1 ] {} <Error> Application: DB::Exception: Thereisno profile'default'inconfiguration file. 2021.08.07 15:05:30.774617 [ 1 ] {} <Information> Application: shutting down 2021.08.07 15:05:30.774630 [ 1 ] {} <Debug> Application: Uninitializing subsystem: Logging...
When the entire application is shut down,tmshutdownremoves the interprocess communication (IPC) resources associated with the BEA Tuxedo system. The options used bytmbootfor partial booting (-A, -g, -I, -S, -s, -l, -M, -B) are supported intmshutdown. The -boption (allowingtmbootto be ...
You receive the following error message when Windows 8.1 or Windows Server 2012 R2 is shutting down: explorer.exe - Application Error The instruction at<memory address>referenced memory at<memory address>. The memory could not be "<read or write>". ...