Westinghouse AP1000® Nuclear Power PlantThe U.S. Nuclear Regulatory Commission (NRC) requires all existing and new-build nuclearpower plants to conduct an Individual Plant Examination of External Events (IPEEE) inaccordance with Generic Letter 88-20. The International Atomic Energy Agency (IAEA)...
AP1000是西屋公司开发的一种双环路1000 MW的压水堆核电机组,其主要特点有:采用非能动的安全系统,安全相关系统和部件大幅减少、具有竞争力的发电成本、60年的设计寿命、数字化仪空室、容量因子高、易于建造(工厂制造和现场建造同步进行)等,其设计与性能特点满足用户要求文件(URD)的要求。 西屋公司在开发AP1000之前,...
The Westinghouse AP1000 Program is aimed at making available a nuclear power plant that is economical in the U.S deregulated electrical power industry in the near-term. The AP1000 is two-loop 1000 MWe pressurizer water reactor (PWR). It is an uprated version of the AP600. The AP1000 ...
The secondary loop thermal systemThermal calculationJava languageNuclear power plantThe thermal system of secondary loop in nuclear unit is a concentrated expression of thermal performance of the plant. Calculating and Analysis the thermal system of secondary loop is an important......
中国AP1000核电厂人因工程和控制室设计安全审评综述.pdf,THE OVERVIEW IN SAFETY REVIEW OF HUMAN FACTORS ENGINEERING AND CONTROL ROOM DESIGN IN CHINESE AP1000 NUCLEAR POWER PLANT —YAN.FENG 1 Introduction about AP1000 2 Review process 3 Review concerns Introd
The AP600 is an advanced 600 MWe nuclear power plant that uses the forces of nature and simplicity of design to enhance plant safety and operations and reduce construction costs. Westinghouse is in the process of obtaining design certification for the AP1000 — a more powerful plant based on ...
forAP1000NuclearPowerPlantIRWST XIAOSan-ping , QIANHui , WUHao , CHENShu-shan (ShanghaiBranch,ShenzhenChinaNuclearPowerDesignCo,Ltd,Shanghai200241,China) Abstract : AFTFathomcodewasusedtocalculatethelowpressuresafetyinjectionof AP1000nuclearpowerplantin-containmentrefuelingwaterstoragetank ( IRWS T ) .The...
Westinghouse AP1000 nuclear power plant
Nuclear power plantWater storage tankRing baffleFluid-structure interactionDynamic responseAP1000 is a standard design developed by Westinghouse for an advanced generation III+ nuclear power plant (NPP) utilizing passive features. Water storage tank of AP1000 plays an important role in cooling down ...
in this paper, according to the westinghouse ap1000 nuclear power plant construction practice of modular build quality control of key and difficulty of the analysis and puts forward some measures. keywords: modular build; the westinghouse ap1000 module; quality control 中图分类号:o213.1文献标识码...