Column: ACE Excel 3 C18-Amide Dimensions: 150 x 4.6 mm Part Number: EXL -1112-1546U Mobile Phase: MeOH/MeCN (90:10 v/v) Flow Rate: 1 mL/min Temperature: 20 °C Detection: UV, 280 nm Analytes 1. Menadione (Vitamin K3) 2. Retinol (Vitamin A) 3. Vitamin A acetate 4. Ergocal...
Column: ACE Excel 3 C18-Amide Dimensions: 250 x 2.1 mm Part Number: EXL -1112-2502U Mobile Phase: 40 mM ammonium phosphate pH 2.5 in H2O Flow Rate: 0.21 mL/min Injection: 5 μL Temperature: 25 °C Detection: UV, 214 nm Analytes 1. Oxalic acid 2. Tartaric acid 3. Malic acid 4....
Column:ChromCore HILIC-Amide, 5 μm Dimension:4.6×150 mm Mobile Phase:A)乙腈 B)水 Gradient:t (min)%A%B 07624 57624 205842 245842 267624 307624 Flow Rate:1.0 mL/min Temperature:30°C Injection:10 μL Detection:ELSD Sample:巴戟天配方颗粒 Peaks:1.蔗糖 2. 1-蔗果三糖 3.耐斯糖 4.巴戟...
The TTX was eluted from the column by 0.1mL of 10% acetic acid solution, and was directly injected into LC–MS/MS. An Agilent 1200 HPLC system equipped with a HILIC separation column (Zorbax HILIC Plus 2.1×100mm, 3.5μm) was used for isocratic elution, with a mobile phase of 10mM ...
Column: XBridge™ Amide, 3.5 μm, 4.6 x 250 mm Mobile Phase A: 80/20 acetonitrile/water with 0.2 % triethylamine Mobile Phase B: 30/70 acetonitrile/water with 0.2 % triethylamine Gradient: Time (min) 0.00 21.00 21.01 33.00 Profile %A %B 100 0 40 60 100 0 100 0 Flow Rate: 1.0...
TSKgel Amide-80 Series 说明书 Rev. CO069010 Packed Columns for Normal Phase Chromatography TSK gel Amide-80 Series INSTRUCTION MANUAL TOSOH CORPORATION
The column combines an ultra- pure, low-acidity porous silica support with a unique stationary phase that has a polar, embedded amide group linking the sterically protecting diiso- propyl groups with a C14 n-alkyl func- tionality. This new column demon- strates stability in low-pH mobile ...
Column:ChromCore 300 SCX, 5 μm Dimension:4.6×250 mm Mobile Phase: Blue:17g/L NH4H2PO4, pH3.0 (CP2015) Black:95:5 v/v 17g/L NH4H2PO4, pH3.0/MeCN Flow Rate:1.0 mL/min Temperature:30°C Injection:5 μL Detection:218 nm ...
Column care and use BEH Amide ANSWER Flush with 10 empty column volumes of initial mobile phase, and then make an injection. ADDITIONAL INFORMATION If you do not see retention after flushing with 10 empty column volumes in your initial mobile phase, try the following...
Orento extract 20 µg/mL Ginsenoside Rb1 standard 0.010 0.008 0.006 0.004 0.002 0.000 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 min Column: XBridge Amide, 3.5 µm, 4.6 x 150 mm Part Number: 186004869 Mobile P hase : Flow Rate: 80/20 1.4 mL ACN /min / H2O ...