[OK] All nodes agree about slots configuration. >>> Check for open slots... [WARNING] Node 192.168.1.100:7000 has slots in importing state (5798,11479). [WARNING] Node 192.168.1.100:7001 has slots in importing state (1734,5798). [WARNING] Node 192.168.1.101:7002 has slots in importing ...
>>> Performing Cluster Check(using node 10.10.20.243:6379) [OK] All nodes agree about slotsconfiguration. >>> Check for open slots... >>> Check slots coverage... [ERR] Not all 16384 slots are covered by nodes. 因为我只有一个节点,单节点集群,所以使用如下方法来修复节点: ./redis-trib.rb...
[OK] All nodes agree about slotsconfiguration. >>> Check for open slots... >>> Check slots coverage... [ERR] Not all 16384 slots are covered by nodes. 原因: 这个往往是由于主node移除了,但是并没有移除node上面的slot,从而导致了slot总数没有达到16384,其实也就是slots分布不正确。所以在删除节点...
0additional replica(s) [OK] All nodes agree about slotsconfiguration. >>> Check for open slots... >>> Check slots coverage... [ERR] Not all 16384 slots are covered by nodes. 原因: 这个往往是由于主node移除了,但是并没有移除node上面的slot,从而导致了slot总数没有达到16384,其实也就是slots分...
We are having the same issue, getting the io.vertx.core.impl.NoStackTraceThrowable: Failed to connect to all nodes of the cluster error log... I our case we have a custom DNS (CNAME) that points to an AWS Configuration endpoint, and we are running in cluster mode there as well... ...
Hi, using a pic16f18446 on a curiousity development board that has an onboard pickit (Pkob4). The board and chip is fine as my desktop pc uploads to it normally. Switched to a laptop running mplab v5.40 and i get this error when uploading After pressing ok, i...
(type'yes'to accept): yes >>> Nodes configuration updated >>> Assign a different config epoch to each node >>> Sending CLUSTER MEET messages to join the cluster Waitingforthe cluster to join.>>> Performing Cluster Check (using node 172.16.0.138:6379) M: 8fdc7aa28a6217b049a2265b87bff...
For complete information about adding a device pool to Cisco Unified Communications Manager, see the “Device Pool Configuration” section in Cisco Unified Communications Manager Administration Guide for the Cisco Unified Communications Manager version that you are running...
Maximum scale-out[1]12 nodes12 nodes12 nodes Maximum effective capacity[1],[5]67PB67PB67PB Maximum SSD144014401440 Controller chassis form factor2x2U4U; 48 internal SSD slots2U; 48 internal SSD slots Power consumption (median)2718W (with NS224)1950W1232W ...
If going R6 as the FTM then I would strongly recommend going with a minimum of 7 nodes (N+1 as always is relevant). I suggest this mainly for two reasons: - Might permit to slightly lower DG and/or disk sizes a bit to have a better cache-ratio and reduce ove...