9. Analog Output Values Gasoline AFR = Methanol AFR = Lambda = 9.00 + Vout x 1.400 3.96 + Vout x 0.616 0.62 + Vout x 0.096 It is important to observe any analog offsets. Any analog input in a logging system may suffer from a voltage offset, requiring that you always check your ...
Ballenger Motorsports AFR500 Manual
0-5V Output Ethanol values from 6.14 to 12.3:1 AFR 0-5V Output Methanol values from 4.4 to 8.8: AFR Gauge Display/0-5V Output Lambda values from 0.68 to 1.36 Interchangeable black and white faceplates included for customizing gauge appearance (digital gauges only) ...
0-5V Output Ethanol values from 6.14 to 12.3:1 AFR 0-5V Output Methanol values from 4.4 to 8.8: AFR Gauge Display/0-5V Output Lambda values from 0.68 to 1.36 Interchangeable black and white faceplates included for customizing gauge appearance (digital gauges only) ...
NTK Production Grade is the least expensive sensor we recommend for methanol applications. Summary of specific changes to the AFR500v3CAN: Programmable CAN termination resistor. Sensor Averaging Filter setting. O2% output. Fault condition diagnostics. IP, pump cell current output. Sensor Temper...
values from 8.0:1 to 20.0:1 AFR CANbus Output Lambda values from .55 to 2.00 0-5V Output Lambda values from .58 to 1.23 0-5V Output E85 values from 5.7:1 to 12.0:1 AFR 0-5V Output Ethanol values from 5.2:1 to 11.0:1 AFR 0-5V Output Methanol values from 3.75:1 to 8.0:1 ...
Zt-3 + Hacker/Tweaker AFR/Lambda Display Bundle In this kit the Zt-3 Wideband is bundled with the Hacker/Tweaker AFR/Lambda Display board. The Zeitronix Hacker/Tweaker is a very small AFR or Lambda display for the Zt-2 or Zt-3 Wideband Systems. Designed to fit into tight spots, full...
0-5V Output Lambda values from .58 to 1.23(Requires Wiring) 0-5V Output E85 values from 5.7:1 to 12.0:1 AFR(Requires Wiring) 0-5V Output Ethanol values from 5.2:1 to 11.0:1 AFR(Requires Wiring) 0-5V Output Methanol values from 3.75:1 to 8.0:1 AFR(Requires Wiring)...
values from 8.0:1 to 20.0:1 AFR CANbus Output Lambda values from .55 to 2.00 0-5V Output Lambda values from .58 to 1.23 0-5V Output E85 values from 5.7:1 to 12.0:1 AFR 0-5V Output Ethanol values from 5.2:1 to 11.0:1 AFR 0-5V Output Methanol values from 3.75:1 to 8...
The X-Series Wideband UEGO AFR Gauge has a user configurable display via buttons on the gauge face that allows you to change AFR values for different fuels, Lambda or O2%, change the center display to three or four digits, perform a free-air calibration if desired as the sensor ages, and...