* * PMOP programmed – after the atrial tachyarrhythmia ends, the pacing rate is smoothly modulated until the programmed Overdrive Rate is reached. The pacemaker maintains the Overdrive Rate in DDIR mode for a programmed duration (Overdrive Period). When the Overdrive Period expires, the rate ...
起搏患者的AT/AF管理 AT/AF的临床背景AT/AF的诊断、监测及治疗AT/AF的器械(起搏器)管理随访病例分析 AT/AF的临床背景 ▪发病机制▪患病率与危害▪分类 AT/AF的临床背景 房速的疾病特征 ➢常见于阵发性➢在无心脏疾病情况下,能够耐受。➢折返环的构成:快传区,慢传区,单向阻滞。AT/AF的临床背景...
据Israel C报道:54%被起搏器发现的AT能被ATP治疗终止 Israel C.success rate of automatic atrial antitachycardia pacing by a pacemaker implanted in patients with paroxysmal 45、and persistent atrial tachyarrhythmia. Abstract 3454. Circulation.October 31, 2002;102(suppl II,No.18) 92 | MDT ...
Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST). Circulation. 2003;107(12):1614-1619.PubMedGoogle ScholarCrossref 15. Healey JS, Connolly SJ, Gold MR, et al; ASSERT ...
Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording. Verification of the accuracy of onset, offset, and duration of automatic mode switching (AMS) of pacemakers compared with onset and end of atrial fibrillat... G ...
PMOP programmed – after the atrial tachyarrhythmia ends, the pacing rate is smoothly modulated until the programmed Overdrive Rate is reached. The pacemaker maintains the Overdrive Rate in DDIR mode for a programmed duration (Overdrive Period). When the Overdrive Period expires, the rate is ...
The mode of initiation of AF episodes were analyzed within a period of 3 months after implantation. 10 patients (6M and 4F, mean age 69.4+-7.9) were enrolled. 1 patient was in persistent atrial tachycardia (AT) and 1 in persistent AF. 494 AF episodes were detected in the remaining 8 ...
Mean follow-up was 4.6 ± 3.4 years and occurred at death, reoperation with mode change, pacemaker explant, or end of study. During follow-up, 44 patients had a ventricular lead implanted with a mean delay of 2.8 ± 3.1 years (range 1 day-10.4 years) after the primary implantation. A...
Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST) Circulation, 107 (12) (2003), pp. 1614-1619 View in ScopusGoogle Scholar 27. G. Boriani, T.V. Glotzer, M. Santini, et...
After all the possible causes are listed for each symptom, the product is designed to eliminate the problems. Failure mode effects analysis (FMEA): A procedure in which each potential failure mode in every subitem of an item is analyzed to determine its effect on other subitems and on the ...