ABBACS550ParameterList S:参数仅能在传动停止时才能修改代码英文名称Group99:启动数据9901LANGUAGE9902APPLICMACRO9904MOTORCTRLMODE9905MOTORNOMVOLT9906MOTORNOMCURR9907MOTORNOMFREQ9908MOTORNOMSPEED9909MOTORNOMPOWER9910MOTORIDRUN9915MOTORCOSPHIGroup01:运行数据0101SPEED&DIR0102SPEED0103OUTPUTFREQ0104CURRENT0105TORQUE...
4. Set parameter 51.02 to 1 (Transparent mode). 5. Start a "Fieldbus adapter parameter refresh" by setting parameter 51.27 FBA PAR REFRESH to REFRESH. 6. Configure the drive to be controlled from the fieldbus. For an example configuration, see the tables below. Parameters in ACS550 Drive ...
1. Introduction to the ABB frequency converter ACS550 The ABB frequency converter ACS550 is a state-of-the-art device designed to regulate the speed and torque of electric motors in various applications and industries. With its advanced control algorithms and user-friendly interface, it provides ...
Howtoinitialize(create)aparameterset.030 Howtouploadaparametersetfromthedrive.ee32 Howtoviewtheparametersetinformation.34 Howtoeditaparameterset.435 Howtoeditthevalueofaparameterinaset.036 Howtoviewandeditthevaluesofchangedparametersinaset.1..38 ...
0290-4-10 N.m 2xAWG3/0 AWG2 AWG3/0 PIHF-0363-4-10 2*150mm2 70mm2 8-10 150mm2 PIHF-0430-4-10 2x300MCM AWG2/0 N.m 300MCM Parameter setting Under the default setting of ACS510, the parameter 26.19 (enabling or disabling the DC voltage regulator) is used for disabling. ...
(150…550HP) •Safety •Installation •Start-Up •Diagnostics •Maintenance •TechnicalData ACS550TechnicalReferenceManual •DetailedProductDescription –TechnicalproductdescriptionincludingDimensional drawings –Cabinetmountinginformationincludingpower losses –Softwareandcontrolincludingcompleteparameter ...
(long)Parameter viewParameter editExit(Cancel)Enter(save)EnterTime outEnter (long)EnterArrowsBoot ACS150 接口 进线功率连接电压 (U1)200/208/220/230/240 VAC 单相, 用于200 VAC 变频器380/400/41 5/440/460/480 VAC 三相, 用于 400 VAC 变频器一般情况下, 电源电压允许在变频器额定电压±1 0% ...
brightness_1Category Document kind
all found slaves need to be accepted, to ensure that all required data can be correctly added to the project Profinet: In the Profinet Controller 'Diagnostics live list' editor the parameter flag "Assign configuration temporarily" has no effect on writing a device name into a Profinet device. ...
Key words:DriveWindow Light;ACS510inverter;SPFC;PID control [中图分类号]TN773[文献标识码]B[文章编号]1561-0330(2021)11-0089-05 1DriveWindow Light介绍 DriveWindow Light软件适用设备ABB以下系列驱动器ACS550,ACS355,ACS310,ACS320,ACB330, ACB530,ACS510,ACQ550,ACS400,ACS800等。DriveWindow ...