AAPM REPORT NO.106-TG106(加速器束数据的调试设备和程序).pdf,Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM Indra J. Dasa Department of Radiation Oncology, University of Penns
C. Zhu, "Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM.," Medical Physics, vol. 35, no. 9, p. 4186, 2008.Das, I. J., Cheng, C. W., Watts, R. J., Ahnesjo, A., Gibbons, J., Li, X. A., ...
AAPM REPORT No.179-TG179 (图像引导质量保证).pdf,Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179 Jean-Pierre Bissonnettea) Task Group 179, Department of Radiation Physics, Princess Margaret
Also, the size of detector should be relatively small: its outer diameter should be less than half the field dimension to provide accurate data, as described in TG-120.11The choice of detector (item 1) for specific clinical needs has been discussed in the AAPM TG-106 report....
Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55film and scanner selectionsquality assuranceradiochromic film dosimetryspecial clinical applicationsThe use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high level of achievable accuracy ...
内容提示: Quality assurance for image-guided radiation therapy utilizing CT-basedtechnologies: A report of the AAPM TG-179Jean-Pierre Bissonnette a)Task Group 179, Department of Radiation Physics, Princess Margaret Hospital, University of Toronto,Toronto, Ontario, Canada, M5G 2M9Peter A. Balter ...
Since the publication of the AAPM TG in 1994, large bodies of literature and case reports have been published about different kinds of radiation effects on modern technology implantable cardiac devices and patient management before, during and after radiotherapy. This task group report provides the ...
Dieterich S, Cavedon C, Chuang CF, Cohen AB, Garrett JA, Lee CL, Lowenstein JR, d'Souza MF, Taylor DD, Wu X, Yu C (2011) Report of AAPM TG 135: quality assurance for robotic radiosur- gery. Med Phys 38:2914Dieterich S, Cavedon C, Chuang CF et al. Report of AAPM TG 135: ...
In this work we analyze the differences, advantages and disadvantages between NEMA NU-2 and AAPM TG 126 methods for PET IQ. Measurements were performed on a Siemens mCT Biograph PET-CT System and two phantoms were used: IEC/NEMA Body Phantom (for NEMA measurements) and PET ACR Phantom (for...
doi:10.1118/1.3626480Medical Physics