The structural and magnetic properties of the ThCr2Si2-type solid solution LaMn2(Ge1−xSix)2 (x = 0.0 to 1.0) have been investigated employing a combination of X-ray diffraction, magnetization and neutron diffraction measurements, which allowed e
Advanced X-ray imaging techniques, such as X-ray fluoroscopy, have significantly enhanced the quality of medical care1,2. Reducing the X-ray dose rate would reduce the harm to patients and enable new applications in X-ray imaging, such as X-ray video techniques3. However, the lowest dose ...
Cells are labelled with fluorescent dye and then passed, in suspending medium, through a narrow dropping nozzle so that each cell is in a small droplet. A laser-based detector system is used to excite fluorescence, and droplets with positively fluorescent cells are given an electric charge. ...
Fig. 6 shows examples of the grown SmOFe1−xCoxAs crystals labelled by their different nominal Co contents. In almost any experiment, plate-like SmOFe1−xCoxAs crystals are yield which show lateral dimensions of up to 4.8mm and a thickness of up to 0.06mm, and are, therefore, ...
During our work on the phase diagram of the ternary Li–Sb–Sn system, the existence of a new ternary Li-rich compound was indicated from powder X-ray patterns of several samples showing additional but comparable diffraction peaks. From the single-crystal structure refinement the chemical formula...
48-bit HED data packages consists of 12-bit event energy, 2-bit detector address, 27-bit time stamp of 27.8 ns resolution and various flag bits. The read-out stream may contain normal events, pile-up events (labelled fast events, which also contain valley data, and will be explained ...
Mutations are labelled according to the first affected male screened per family. (b) Cross-species conservation of the mutated amino acid Asp133 (D133) is shown beneath the protein, in red (right), and PHYRE-based63 three-dimensional modelling of the whole of human PIH1D3 shows a surface ...
13C, 15N XMAP-Ct-labelled samples for NMR were prepared at 0.2–0.5 mM in 20 mM sodium phosphate buffer, 150 mM NaCl and 0.25 mM TCEP at pH 5.9, 7.0 and 7.5, respectively. The 13C, 15N TD4-XMAP-Ct complex was prepared in 20 mM Tris buffer, 150 mM NaCl, 0.1% LDAO (N,N-...
the upload spreadsheet500includes the control code504(e.g., “Measure”), which may indicate that the column labeled by the control code504is a column of measures within the upload spreadsheet500. In the example embodiments shown, the control code504has replaced the header cell labelled “Sales...
FIG. 8 consisting of parts A-D, is a timing diagram for explaining the functional features of the new filter device. DESCRIPTION OF A PREFERRED EMBODIMENT The computed projection radiography (CPR) system depicted in FIG. 1 comprises a casing 10 that contains an X-ray tube which is not vis...