Unified glare ratingStandard room dimensionLuminaire layoutIn interior lighting design, the maintained illuminance and unified glare rating (UGR) are two important design criteria. The lumen method of design is a simple method often used to calculate the average maintained illuminance on a reference ...
网络统一眩光值 网络释义 1. 统一眩光值 统一眩光值(Unified glare rating)它是度量处於视觉环境中的照明装置发出的光,对人眼引起不舒适感主观反应的心理参量,其… www.ecolighting.com.tw|基于19个网页
CALCULATION AND PRESENTATION OF UNIFIED GLARE RATING TABLES FOR INDOOR LIGHTING LUMINAIRES This document specifies the necessary information and the process required for the production of the standard-condition CIE UGR table for a luminaire at spacing to height ratio (RSH) of 1:1. The... Referenc...
By cross referencing room dimensions and reflectance values in this table, UGR can be estimated considering endwise and crosswise view of the fixtures. If a single value is to be used, per CIE 117-1995, the largest value in the table must be used. This UGR calculation method is popular ...
求翻译:Unified glare rating是什么意思?待解决 悬赏分:1 - 离问题结束还有 Unified glare rating问题补充:匿名 2013-05-23 12:21:38 统一眩光等级 匿名 2013-05-23 12:23:18 正在翻译,请等待... 匿名 2013-05-23 12:24:58 Unified glare rating 匿名 2013-05-23 12:26:38 统一的眩光...
In the CIE TC3-13 meeting in 1993, the unified glare rating (UGR) proposed by K . S Oresen was approved for adoption in the TC report . In Japan , the "G-Classification" which classifies luminaires based on the CIE Glare Safeguard System , has been used. Therefore, it is important ...
UGR stands for Unified Glare Rating. It is an objective measure of glare that is used by lighting designers to help control the risk that occupants of a building will experience glare from the artificial lighting. UGR values range from 40 (extremely high glare) to 5 (very low glare). In ...
April 2, 2019 PERMITTED USES TABLE Z= Permit from Zoning Officer P= Planning Board Review A= Board of Adjustment Special Use Permit E= Elected Body Special Use Permit USE TYPE Note: See Overlay Zoning Districts for prohibited uses within specific districts. RESIDENTIAL USES Residential Building,...
Porsch T., Funke C., Schmidt F., Schierz Ch., Measurement of the Unified Glare Rating (UGR) based on using ILMD. Proc. of the 28th CIE SESSION, Manchester, UK, June 28 - July 4, 2015. 536-542Measurement of the Unified Glare Rating (UGR)based on using ILMD. Tobias Porsch. CIE...
Unified Glare Rating (UGR) and subjective appraisal of discomfort glare The study investigated the correlation between the subjective glare rating and the Unified Glare Rating (UGR). Experiments and analyses were carried out. The results showed that there was a good correlation between the subjective...