Table 1. Thermocouple Types Thermocouple Type Metal Content in Positive Leg Metal Content Temp in Negative Leg Range (°C) B 70.4% Platinum (Pt) 93.9% Pt, 6.1% 0 – 1820 29.6% Rhodium (Rh) Rh E 90% Nickel (Ni) 55% Copper -270 – 1000 10% Chromium (Cr) (Cu) 45% Ni J 99.5%...
Type T Accuracy Standard+/- 1.0°C or +/- .75% Special Limits of Error+/- 0.5°C or 0.4% Download the ITS-90 Reference Table for Type T Thermocouples Here (PDF) Type E Thermocouple (Nickel-Chromium/Constantan) The Type E has a stronger signal & higher accuracy than the Type K or ...
t型热电偶分度号(Ttypethermocouplenumber) Ttypethermocoupleindexnumber(temperatureandvoltage correspondingconversiontable) C0-1,-2,-3,-4,-5,-6,-7,,-8,-9,-10 ThermoelectricVoltageinmV -270-6.258 -260,-6.232,-6.236,-6.239,-6.242,-6.245,-6.248,-6.251, ...
Type T Thermocouple Table Copper/Copper-Nickel, Electromotive force as a function of temperature E/µV 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -6258 -6232 -6236 -6239 -6242 -6245 -6248 -6251 -6253 -6255 -6256 -6180 -6187 -6193 -6198 -6204 -6209 -6214 -6219 -6223 -6228 -6105 ...
Type J Accuracy (whichever is greater): Standard: +/- 2.2C or +/- .75% Special Limits of Error: +/- 1.1C or 0.4% Consideration for bare wire type J thermocouple applications: The Type J Is Well Suited To Oxidizing Atmospheres Type J Thermocouple Reference Table: Type...
t型热电偶分度号(T type thermocouple number) T type thermocouple index number (temperature and voltage corresponding conversion table) C 0-1, -2, -3, -4, -5, -6, -7,, -8, -9, -10 Thermoelectric Voltage in mV -270 -6.258 -260, -6.232, -6.236, -6.239, -6.242, -6.245, -6.248...
Thermocouple Input Types and Ranges Table Input Type Range Accuracy* (°C) Resolution (°C) J -200 to 1200°C (-328 to 2192°F) ±1.5 0.019 K -200 to 1372°C (-328 to 2501°F) ±1.5 0.024 T -200 to 400°C (-328 to 752°F) ±1.5 0.022 E -200 to 1000°C (-328...
英['θɜ:mə'kʌpl] 美['θɜməˌkʌpəl] 是什么意思 n. 热电偶(热电偶是根据热电效应测量温度的传感器,是温度测量仪表中常用的测温元件);温差电偶; 英英释义 thermocouple[ 'θə:məu,kʌpl ] n.a kind of thermometer consisting of two wires of different metals that are...
The connector pin out is as shown in the accompanying figure. To maintain the proper polarity and the use of thermocouple materials from the sensor to your measurement or control instrument, we recommend one of Omega'sM8 Thermocouple Extension Cables(listed in the ordering table below). ...
3-A sanitary type T, J, and K thermocouple probes with polypropylene or stainless steel protection heads. For use in Food & Beverage, Pharmaceuticals and wash down areas. View Specs See More Items from this Family (36) TCS-H-CB Integral Cable Thermocouples Type T, J & K Sanitary Probes ...