120VAC,95A 240VAC,65A 600VAC,35A Dielectric strength 2200Vrms Insulation resistance 100 megaohms Contact resistance 10 miliohms Switch mountings 3-Hole Approvals UL Recognized CSA Certified CE Resources Series 24 LOR w/Push-to-Trip Feature ...
Output Feedback External relay status feedback Dual Output 2 PNP outputs; 300mA drive load capacity per circuit Reset from lockout conditions Input high pulse width of 100ms - 1.5s during lockout conditions and waiting for reset Housing protection class Ip65 (IP67, IP69 o...
Output Feedback External relay status feedback Dual Output 2 PNP outputs; 300mA drive load capacity per circuit Reset from lockout conditions Input high pulse width of 100ms - 1.5s during lockout conditions and waiting for reset Housing protection class Ip6...
144 NX-Series Controllers - WebConsole & Programming Guide 12 Overview Overview NetLinx NX Integrated Controllers NetLinx NX Integrated Controllers (Masters) can be programmed to control RS-232/422/485, Relay, IR/Serial, and Input/Output devices using the NetLinx Studio application (versio...
Updated: December 16, 2024 Chapter: Index
1 2 3 + IDC - 10 WATLOW Series 942 User's Manual Install and Wire, Chapter 2 Output 1 Wiring Solid State Relay With Contact Suppression, Output 1 Model # 942A - _ B _ _ - _ 000 Solid State Relay, Form A, 0.5 Amp External 17 N.O. Load 18 COM. Fuse L2 L1 Solid State ...
Recommended Action Try unlocking the user using the clear_aaa_local_user_lockout command or adjusting the maximum number of consecutive authentication failures that are tolerated. 113007 Error Message %ASA-6-113007: User user unlocked by administrator Explanation A locally configured user that was ...
If the parameter doesn't already exist, add the following line to the end of the file: ENCRYPT_METHOD SHA512 SICAM 8 Series, Administrator Security, Manual DC8-131-2, Edition 07.2023 35 Measures for System Hardening 2.2 SICAM 8 Series ² Set up an account lockout for the password ...
Hardware Setup, Chapter 1 WATLOW Series 988 User's Manual 1.3 DIP Switches ç CAUTION: The lockout DIP switch makes the Setup and Factory menus unavailable. Configure all the Setup and Factory menus before lock- ing them out. Fail- ure to do so could result in damage to equipment in ...
OPLC Swichgage, surface mount, with low limit lockout switch OPLCE Swichgage, panel mount square case OPLFC Swichgage, panel mount OPLBP* Swichgage, surface mount, with latching control relay OPLBPE* Swichgage, panel mount square case, with latching control relay OPLG Murphygage, surf...