a cut— 口子 · 创口 查看更多用例•查看其他译文 使用DeepL翻译器,即刻翻译文本和文档 随打随译 世界领先的质量 拖放文件 立刻翻译 ▾ 外部资源(未审查的) Tissue culture extract purification The primary variable characterizing a dialysis membrane isitsMolecular Weight Cut-Off(MWCO). ...
3.1 Membrane molecular weight cut-off NF membrane possesses molecular weight cut-off (MWCO) ranging from 200 Da (tight) to 500 Da (loose).13 Note that MWCO is a molecular weight in which 90% of compound is rejected. MWCO is widely used to estimate organic molecule rejections, but it does...
Collagen peptides were extracted and purified by acetic acid with sonication, followed by two-stage hydrolysis with 0.1% pepsin and 5% flavourzyme, and ultrafiltration with 500 Da molecular weight (MW) cut-off dialysis membrane. Animal experiments were performed with collagen p...
The COF membrane was fabricated by a vacuum-assisted self-assembly method on a polyacrylonitrile (PAN) substrate (Fig.2a). The PAN substrate with an average surface pore size of 30 nm (Supplementary Fig.13) was uniformly deposited by a dense and defect-free TpTGCl@CNFs-X membrane, as s...
(Cambridge Isotope Laboratory) was used for the production of 2 H13C15N-Cp183 in a 3-ml-translation reaction experiment for NMR studies. A dialysis membrane with a molecular weight cut-off of 10 kDa has been used, and protein synthesis has been performed for 16 h at 22 °C under...
These barrier functions are maintained by the expression of numerous membrane transport systems such as ATP-binding cassette transporters, solute carrier families and peptide transporters allowing the directed transport of water, ions, nutrients, and biologically active compounds into the CSF from the ...
Each of the 96 wells has a separate regenerated cellulose membrane inside meaning no cross contamination or leakage between wells. The size of the compounds that pass through the membrane are determined by its Molecular Weight Cut Off (MWCO). The Swissci Diaplate comes as standard with a special...
Animal venoms, distinguished by their unique structural features and potent bioactivities, represent a vast and relatively untapped reservoir of therapeutic molecules. However, limitations associated with comprehensively constructing and expressing highly complex venom and venom-like molecule libraries have preclu...
LysM samples at a concentration of 50 μM were extensively dialysed using a 3.5 kDa molecular weight cut-off membrane (SPECTRUM Labs) at 4 °C against 50 mM sodium acetate (pH 5.0), and degassed before DSC measurements (MicroCal VP-DSC calorimeter). The dialysis buffer was used ...
The serum mineral complex was characterized by filtration using Ultrafree CL filtration devices with a 300-kDa molecular mass cut-off membrane. In a typical experiment, blood was obtained from 2 control rats and from 2 rats 6 h after a dose of 8 mg of etidronate/100 g of body weight, and...