The utility model discloses a measuring system of pulse width modulation pulse signals, which comprises a converter/ inverter, an insulated gate bipolar translator (IGBT) module and an oscilloscope. The pulse-width modulation (PWM) pulse signal output end of the converter/ inverter is connected ...
Oscilloscope operating settings optimize the recording of these signal replicas by improving the measurement signal-to-noise ratio. This improved TLP system is especially useful when very short width pulses on the order of less than 10 nanoseconds are used to test the DUT's response. 展开 ...
PURPOSE: To easily calculate the delay time of a signal only by incorporating a logical integrating circuit even when there is no measuring device such as an oscilloscope when the delay time of the signal is measured in a delay time measuring system measuring the delay time to an input clock...
6 Maximum allowable input voltage KT test board and Oscilloscope 140vp-p, pulse width 0.5ms, intermittent: 10ms 7 Mean time between failures aging test rack Test temp 25±5ºC 6.Precautions 1. Please confirm with us which industry will be used before p...
Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time out (Dropout), Pattern 6000 counts Digital Multimeter, Support DCV, ACV, DCI, ACI, Resistance, Diode, Capacitance, Continuity test 3 one-button shortcuts for Oscilloscope, Multimet...
6 Maximum allowable input voltage KT test board and Oscilloscope 140vp-p, pulse width 0.5ms, intermittent: 10ms 7 Mean time between failures aging test rack Test temp 25±5ºC 5.Precautions 1. Please confirm with us which industry will be used before purchasing...
parameters (a pulse width Wt, rise time (=fall time) αt, cycle Tt, and timing of measurement point tm), the pulse being supplied from the pulse generator 3 to the FET 1, and frequency characteristics of the drain measuring system including the oscilloscope 9, the cables, and the bias ...
The overall structure of the VFTO measurement system is shown in Figure 11, which mainly includes five parts: a capacitive voltage divider, signal conditioning sensor, electrical–optical signal converter, field acquisition oscilloscope, and remote-control computer. The input port of the signal conditio...
The gain and phase can also be measured at multiple points with an oscilloscope using Equation 7 for the gain and Equation 8 for the phase, where ∆t is the time delay between the input and output voltages and f is the frequency of the input signal. The data is then plotted versus ...
A powerful pulse generator generates pulses with a repetition rate of up to 12.5 MHz/25 MHz; The pulse width can be set to 15 ns to 999 s, with a resolution of 5 ns. The rise/fall time is optional within the range of 8 ns to 500 ns, which is v...