72359-4 A high precision linear solid state opto-electronic critical angle refractometer which is adapted to continuously measure the refractive index of a liquid over a narrow range of refractive indices when immersed into liquid being measured. The device is adapted for use in both industrial and...
Laser-driven ion sources are interesting for many potential applications, from nuclear medicine to material science. A promising strategy to enhance both ion energy and number is given by Double-Layer Targets (DLTs), i.e. micrometric foils coated by a ne
2.5. Brewster angle microscopy An EP3 single wavelength ellipsometer from Accurion (Göttingen) with an antivibration system (Vario 40–100) from the same manufacturer was used in BAM setup, i. e. light polarized in the plane (p) of incidence, from a laser of 532 nm wavelength (50 mW)...
We have eliminated the extrapolation to 0 = oo scattering angle because the angle effect on the apparent spinodal temperature is certainly small at f} = 30°, and would at warst produce a very small parallel shift of the spinodallocus in a phase diagram. We comment on the work of Chu et...
The key difference between refractive index and critical angle is that refractive index is the ratio of the velocity of a light beam in the air to the velo
Onofri F., Critical Angle Refractometry: for simultaneous measurement of particles in flow size and relative refractive index, Part. and Part. Syst. Charact. Vol. 13: 119-127 (1999).Onofri F (1999) Critical angle refractometry: for simultaneous measurement of particles in flow size and ...
N. North, Refractive index measurement of absorbing and turbid fluids by reflection near the critical angle, Meas. Sci. Technol. 6, 6th ed., pp. 8, (Nov. 21, 1994).Meeten G H and North A N 1995 Refractive index measurement of absorbing and turbid fluids by reflection near the critical...
and North, A.N., "Refractive index measurement of turbid colloidal fluids by transmission near the critical angle", Meas. Sci, Technol. 2, 441-447, 1991.G.H. Meeten, A.N. North, Refractive index measurement of turbid colloidal fluids by transmission near the critical angle, Meas. Sci. ...
A new method of measuring the refractive index of a prism using the critical angle is described. The accuracy of the technique and tolerances on angle measurements are discussed. Two standard prisms were measured using this method and the values agreed with those measured by the minimum deviation...
Explosion protected controls for zero and span settings are located to the exterior of a purged safe enclosure containing the system.doi:US5223142 AKolbert, Jason HUSUS5223142 * Aug 18, 1992 Jun 29, 1993 Biotage Inc. Production chromatography process using a critical angle refractive index ...