Results of time history analyses show that the proposed method effectively determines the storey-wise column size for various building plans, heights up to 12 stories, and design base displacements up to 350mm for target storey drifts up to 0.25%.Manisana, Rajkumar...
The function of building is common office with 1.7 kPa super-imposed dead load and 3 kPa live load. The spans of the columns were 6 m and 9 m in two orthogonal directions. Member sections are standard I-section with universal beam size UB 406 × 140 × 39 and column size UC 610 ×...
It has been used in many buildings such as 200 two-storey residential buildings and 1 eight-storey residential building. Five 17-storey buildings are currently being designed. However, the seismic behavior of the entire SCFST column frame has not been experimentally studied. The pseudo-dynamic ...
5. packing,loading and container on destination 6. Weifang Tailai steel structure Co.Ltd. one of the market leader for steel structure building business in China. more than 14year's experience . ---Weifang tailai is a professional steel structure enterpris...
Type of Steel For Building Structure H-Section Steel Window Style Sliding or Roller Window Door Style Swing, Sliding or Rooler Door Transport Package as Per Customer′s Requirements Origin Cangzhou,Hebei,China Low Cost Factory Warehouse Workshop Light Prefabricated Steel Stru...
Manual for the design of timber building structures to Eurocode 5 IStructE-TRADA: Manual for the design of timber building structures to Eurocode 5. IStructE, London, 2007.IStructE & TRADA. Manual for the design of timber building structures to Eurocode 5. s.l. : The Institution of Structura...
8.Usage: concrete forming of circular column in building 9.Description of goods: A:consist of two piece of semi-circle plywoods and steel belts B:plywood have U.N slots at edge and can be joined seamlessly C:steel belt fix the formwork every 200mm-300mm Send your ...
8.Usage: concrete forming of circular column in building 9.Description of goods: A:consist of two piece of semi-circle plywoods and steel belts B:plywood have U.N slots at edge and can be joined seamlessly C:steel belt fix the formwork every 200mm-300mm ...
5. So, the required sum of plastic moment of first storey columns, ∑i=1ncMc.i.1, reduced due to the contemporary action of the axial force, can be computed by: Download: Download high-res image (154KB) Download: Download full-size image Fig. 5. Collapse Mechanisms of LCFs for im=...
The column grid layout of the prototype building is 6 m × 9 m, and the storey height is 4.2 m. Considering the space limitation of the laboratory, the subassembly was down scaled to one-thirds of their original size, resulting in the test specimen in Fig. 1 with a layout of Load-...